3-2
3.1 Pre-Trip Inspection
Perform a pre-trip inspection of each component and take remedial actions if necessary so that the unit will
operate normally. Pre trip inspection includes items are listed below.
(1) Appearance inspection of unit
Physical damage
Casing insulation through penetration
Drain hose (dust and clogging)
Power cable and plug damage
Condition of refrigerant piping cramp
Condition of each sensor installation
Loose mounting sections
Bolts and nuts ----- Casing frame, compressor, fan motor, control box, inverter box
Cable glands ----- Control box
Conditions of control box cover packing (water-proof)
Magnetic contactor contact point
Condition of Inverter box cover packing (water-proof)
(2) Inspection before unit operation
Refrigerant leakage inspection
Power voltage inspection (Automatic PTI range)
(3)
Operation inspection of safety
device and control equipment
HPS ……
Check for proper activation of switch when high pressure
Safety device
is raised by stopping the condenser fan motor.
Control equipment Solenoid valve ……
Inspection of operation (open and close) and leakage
EFM ……Speed switchover and rotating direction
EEV, EMV, DMV ……
Inspection of operation (open and close) and leakage
(4) Operation in each mode
Pull-down 0 Pull-down time, voltage and current
Chilled control 0 Electronic temperature recorder calibration
Return, supply air temperature differential, voltage and current
Defrosting Defrosting time
Pull-down -18
Pull-down time, evaporator fan motor speed switchover
Frozen control -18 Electronic temperature recorder calibration
(Temperature difference and rotating direction)
voltage and current
Dehumidification operation and humidity sensor inspection
Remaining frost inspection
(5) PTI report preparation
Consumables
Wake-up battery: 2 years
Humidity sensor: Inspect every year. Replace when appropriate.
Refrigerant: Inspect at PTI. Repair as needed. (malfunction caused by moisture entering etc.)
Power plug: Inspect during PTI. Repair as needed.
Power cable: Inspect during PTI. Repair as needed.
0301-10LX10F11BEn.indd3-20301-10LX10F11BEn.indd3-2 2014/11/1916:36:322014/11/1916:36:32
https://daikin-p.ru

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin LX10F11B and is the answer not in the manual?

Daikin LX10F11B Specifications

General IconGeneral
BrandDaikin
ModelLX10F11B
CategoryInverter
LanguageEnglish

Related product manuals