Outdoor Unit Si04-306
170 Removal Procedure
2.4 Removal of the Reactor
Procedure Warning Be sure to wait 10 minutes or more after turning off all power supplies
before disassembling work.
Step
Procedure Points
Remove the electrical box.
1. Remove the
partition plate
.
1
Release the clamp by
pliers.
2
Loosen the two screws
of the partition plate.
The partition plate is fixed to
the bottom frame with a
claw.
(R2724)
Claw