COOL operation HEAT operation AUTO operation DRY or FAN operation
18-32ËšC 10-30ËšC 18-30ËšC
îš„ Operating conditions
îš„ Recommended temperature setting
îš„ Tips for saving energy
.
îš„ Notes on the operating conditions
MODE Operating conditions If operation is continued out of this range
COOL
HEAT
DRY
• Operation outside this humidity or temperature range may cause a safety device to disable the system.
• The displayed items on the LCD will change whenever either one of the buttons is
pressed.
The temperature setting is
not variable.
Press to raise the temperature and press to lower the
temperature.
• For cooling: 26-28˚C
• For heating: 20-24˚C
• Be careful not to cool (heat) the room too much.
Keeping the temperature setting at a moderate level helps save energy
• Cover windows with a blind or a curtain.
Blocking sunlight and air from outdoors increases the cooling (heating) effect.
• Clogged air filters cause inefficient operation and waste energy. Clean them once in about every 2 weeks.
• The outdoor unit consumes some power to have its electric components work even while it is not operating.
Connecting outdoor unit RXG25/35: 1-15W
Other outdoor units: 15-20W
The outdoor unit consumes 40 to 55W of power at the time of compressor preheating.
• If you are not going to use the air conditioner for a long period, for example in spring or autumn, turn the breaker off.
• Use the air conditioner in the following conditions.
• A safety device may work to stop the operation.
(In multi system, it may work to stop the operation of the
outdoor unit only.)
• Condensation may occur on the indoor unit and drip.
Outdoor temperature : <2/3/4/5MXS> –10-46˚C
<RXG> –10-46˚C
Indoor temperature : 18-32ËšC
Indoor humidity : 80% max.
Outdoor temperature : <2MXS> –10-24˚C
<3/4/5MXS> –15-24˚C
<RXG> –15-24˚C
Indoor temperature : 10-30ËšC
Outdoor temperature : <2/3/4/5MXS> –10-46˚C
<RXG> –10-46˚C
Indoor temperature : 18-32ËšC
Indoor humidity : 80% max.
• A safety device may work to stop the operation.
• A safety device may work to stop the operation.
• Condensation may occur on the indoor unit and drip.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi NX FFQ50B8V1B and is the answer not in the manual?

Daikin Super Multi NX FFQ50B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi NX FFQ50B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals