EasyManuals Logo

Daikin VRVII User Manual

Daikin VRVII
385 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #319 background imageLoading...
Page #319 background image
Troubleshooting by Indication on the Remote Controller
314
3.65
U8
Transmission Error
between Main and Sub
Remote Controllers
Remote Controller Display
U8
Applicable Models
All indoor models
Method of Error Detection
In case of controlling with 2-remote controller, check the
system using micro-computer if signal transmission
between indoor unit and remote controller (main and sub)
is normal.
Error Decision Conditions
Normal transmission does not continue for specified
period.
Supposed Causes
Transmission error between main and sub remote
controller
Connection between sub remote controllers
Defective remote controller PCB

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin VRVII and is the answer not in the manual?

Daikin VRVII Specifications

General IconGeneral
BrandDaikin
ModelVRVII
CategoryAir Conditioner
LanguageEnglish

Related product manuals