Troubleshooting by Indication on the Remote Controller
63
3.7
A7
Swing Flap Motor (M1S)
Abnormality
Remote Controller Display
A7
Applicable Models
R-22: FXC, FXA, FXF, FXH, FXK
R-410A: FXCQ, FXHQ, FXKQ, FXUQ
Method of Error Detection
Utilizes ON/OFF of the limit switch when the motor turns.
Error Decision Conditions
When ON/OFF of the micro-switch for positioning cannot
be reversed even though the swing flap motor is
energized for a specified amount of time (about 30
seconds).
Error code is displayed but the system operates
continuously.
Supposed Causes
Defective swing motor
Defective connection cable (power supply and limit
switch)
Defective airflow direction adjusting flap-cam
Defective indoor unit PCB