Code number
AHF005
IP00
IP20
Code number
AHF010
IP00
IP20
Filter
current
rating
Typical
motor
VLT model
and current
ratings
Losses
Acoustic
noise
Frame size
AHF005 AHF010
[A] hp [kW]
hp
[kW]
[A] [W] [W] [dBA] AHF005 AHF010
2x130B3153
2x130B3152
2x130B3151
2x130B3136
650 475
[355]
P475
[P355]
647 2812 1904 <80
130B1448+130B1449
130B1259+130B1260
130B1370+130B1389
130B1216+130B1217
685 550
[400]
P550
[P400]
684 2798 2080 <80
2x130B1449
2x130B1260
2x130B1389
2x130B1217
762 600
[450]
P600
[P450]
779 3020 2350 <80
130B1449+130B1469
130B1260+130B1261
130B1389+130B1391
130B1217+130B1228
861 650
[500]
P650
[P500]
857 3362 2717 <80
2x130B1469
2x130B1261
2x130B1391
2x130B1228
960 750
[560]
P750
[P560]
964 3704 3084 <80
3x130B1449
3x130B1260
3x130B1389
3x130B1217
1140 850
[630]
P850
[P630]
1090 4530 3525 <80
2x130B1449+130B1469
2x130B1260+130B1261
2x130B1389+130B1391
2x130B1217+130B1228
1240 950
[710]
P950
[P710]
1227 4872 3892 <80
3x130B1469
3x1301261
3x130B1391
3x130B1228
1440 1075
[800]
P1075
[P800]
1422 5556 4626 <80
2x130B1449+2x130B1469
2x130B1260+2x130B1261
2x130B1389+2x130B1391
2x130B1217+2x130B1228
1720 1350
[1000]
P1350
[P
1000]
1675 6724 5434 <80
Table 5.12 Advanced Harmonic Filters 380–415 V, 50 Hz, E- and F-frames
Code
number
AHF005
IP00
IP20
Code
number
AHF010
IP00
IP20
Filter
current
rating
Typical
motor
VLT model and
current ratings
Losses
Acoustic
noise
Frame size
AHF005 AHF010
[A] hp [kW] hp [kW] [A] [W] [W] [dBA] AHF005 AHF010
130B3131
130B2869
130B3090
130B2500
204 150 [110] N150
[N110]
204 1080 743 <75 X6 X6
130B3132
130B2870
130B3091
130B2700
251 175 [132] N175
[N132]
251 1194 864 <75 X7 X7
130B3133
130B2871
130B3092
130B2819
304 250 [160] N250
[N160]
304 1288 905 <75 X8 X7
130B3157
130B3156
130B3155
130B3154
325
Paralleling for 475 hp [355 kW]
1406 952 <75 X8 X7
130B3134
130B2872
130B3093
130B2855
381 300 [200] N300
[N200]
381 1510 1175 <77 X8 X7
130B3135
130B2873
130B3094
130B2856
480 350 [250] N350
[N250]
472 1850 1542 <77 X8 X8
2x130B3133
2x130B2871
2x130B3092
2x130B2819
608 450 [315] N450
[N315]
590 2576 1810 <80
Table 5.13 Advanced Harmonic Filters, 380–415 V, 60 Hz, D-frame
How to Order
Design Guide
MG34S222 Danfoss A/S © Rev. 2014-02-10 All rights reserved. 99
5 5

Table of Contents

Other manuals for Danfoss VLT AutomationDrive FC 300

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT AutomationDrive FC 300 and is the answer not in the manual?

Danfoss VLT AutomationDrive FC 300 Specifications

General IconGeneral
BrandDanfoss
ModelVLT AutomationDrive FC 300
CategoryDC Drives
LanguageEnglish

Related product manuals