An X marked in Table 4.2 means that action occurs. A warning precedes an alarm.
No. Description Warning Alarm/Trip Alarm/Trip Lock
1 10 volts low X
2 Live zero error (X) (X)
3 No motor (X)
4 Mains phase loss (X) (X) (X)
5 DC link voltage high X
6 DC link voltage low X
7 DC overvoltage X X
8 DC undervoltage X X
9 Inverter overloaded X X
10 Motor overtemperature (X) (X)
11 Motor thermistor overtemperature (X) (X)
12 Torque limit X X
13 Overcurrent X X X
14 Ground fault X X X
15 Hardware mismatch X X
16 Short-circuit X X
17 Control word timeout (X) (X)
22 Hoist mechanical brake X
23 Internal fan fault X
24 External fan fault X
25 Brake resistor short-circuit X
26 Brake resistor power limit (X) (X)
27 Brake chopper fault X X
28 Brake check failed (X) (X)
29 Heatsink temp X X X
30 Motor phase U missing (X) (X) (X)
31 Motor phase V missing (X) (X) (X)
32 Motor phase W missing (X) (X) (X)
33 Inrush fault X X
34 Fieldbus communication fault X X
36 Mains failure X X
38 Internal fault X X
39 Heatsink sensor X X
40 Overload of Digital Output Terminal 27 (X)
41 Overload of Digital Output Terminal 29 (X)
42 Overload of Digital Output on X30/6 or Overload of Digital Output on
X30/7
(X)
46 Power card supply X X
47 24 V supply low X X X
48 1.8 V supply low X X
49 Speed limit X
50 AMA calibration failed X
51 AMA check U
nom
and I
nom
X
52 AMA low I
nom
X
53 AMA motor too big X
54 AMA motor too small X
55 AMA parameter out of range X
56 AMA interrupted by user X
Troubleshooting Service Manual
50 Danfoss A/S © Rev. 2014-02-10 All rights reserved. MG94A222
44

Table of Contents

Other manuals for Danfoss VLT FC 100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 100 and is the answer not in the manual?

Danfoss VLT FC 100 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 100
CategoryDC Drives
LanguageEnglish

Related product manuals