4 Parameter Lists
4.1 Parameter Options
4.1.1 Default settings
Changes during operation:
”TRUE”
means that the parameter can be changed while
the frequency converter is in operation and “FALSE” means
that the frequency converter must be stopped before a
change can be made.
4-Set-up:
'All set-up': the parameter can be set individually in each
of the four set-ups, i. e. one single parameter can have
four different data values.
’1 set-up’: data value will be the same in all set-ups.
SR:
Size
related
N/A:
No default value available.
Conversion index:
This number refers to a conversion figure used when
writing or reading by means of a frequency converter.
Conv.
index
100 75 74 70 67 6 5 4 3 2 1 0 -1 -2 -3 -4 -5 -6
Conv.
factor
1 3600000 3600 60 1/60 100000
0
10000
0
10000 1000 100 10 1 0.1 0.01 0.001 0.000
1
0.00001 0.00000
1
Table 4.1
Data type Description Type
2 Integer 8 Int8
3 Integer 16 Int16
4 Integer 32 Int32
5 Unsigned 8 Uint8
6 Unsigned 16 Uint16
7 Unsigned 32 Uint32
9 Visible String VisStr
33 Normalized value 2 bytes N2
35 Bit sequence of 16 boolean variables V2
54 Time difference w/o date TimD
Table 4.2
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
MG16H102 - VLT
®
is a registered Danfoss trademark