Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
16-61 Terminal 53 Switch Setting [0] Current All set-ups FALSE - Uint8
16-62 Analog Input 53 0 N/A All set-ups FALSE -3 Int32
16-63 Terminal 54 Switch Setting [0] Current All set-ups FALSE - Uint8
16-64 Analog Input 54 0 N/A All set-ups FALSE -3 Int32
16-65 Analog Output 42 [mA] 0 N/A All set-ups FALSE -3 Int16
16-66 Digital Output [bin] 0 N/A All set-ups FALSE 0 Int16
16-67 Pulse Input #29 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-68 Pulse Input #33 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-69 Pulse Output #27 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-70 Pulse Output #29 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-71 Relay Output [bin] 0 N/A All set-ups FALSE 0 Int16
16-72 Counter A 0 N/A All set-ups TRUE 0 Int32
16-73 Counter B 0 N/A All set-ups TRUE 0 Int32
16-75 Analog In X30/11 0 N/A All set-ups FALSE -3 Int32
16-76 Analog In X30/12 0 N/A All set-ups FALSE -3 Int32
16-77 Analog Out X30/8 [mA] 0 N/A All set-ups FALSE -3 Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1 0 N/A All set-ups FALSE 0 V2
16-82 Fieldbus REF 1 0 N/A All set-ups FALSE 0 N2
16-84 Comm. Option STW 0 N/A All set-ups FALSE 0 V2
16-85 FC Port CTW 1 0 N/A All set-ups FALSE 0 V2
16-86 FC Port REF 1 0 N/A All set-ups FALSE 0 N2
16-9* Diagnosis Readouts
16-90 Alarm Word 0 N/A All set-ups FALSE 0 Uint32
16-91 Alarm Word 2 0 N/A All set-ups FALSE 0 Uint32
16-92 Warning Word 0 N/A All set-ups FALSE 0 Uint32
16-93 Warning Word 2 0 N/A All set-ups FALSE 0 Uint32
16-94 Ext. Status Word 0 N/A All set-ups FALSE 0 Uint32
16-95 Ext. Status Word 2 0 N/A All set-ups FALSE 0 Uint32
16-96 Maintenance Word 0 N/A All set-ups FALSE 0 Uint32
Table 4.15
4.1.15 18-** Info & Readouts
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
18-0* Maintenance Log
18-00 Maintenance Log: Item 0 N/A All set-ups FALSE 0 Uint8
18-01 Maintenance Log: Action 0 N/A All set-ups FALSE 0 Uint8
18-02 Maintenance Log: Time 0 s All set-ups FALSE 0 Uint32
18-03 Maintenance Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-1* Fire Mode Log
18-10 FireMode Log:Event 0 N/A All set-ups FALSE 0 Uint8
18-11 Fire Mode Log: Time 0 s All set-ups FALSE 0 Uint32
18-12 Fire Mode Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-3* Inputs & Outputs
18-30 Analog Input X42/1 0 N/A All set-ups FALSE -3 Int32
18-31 Analog Input X42/3 0 N/A All set-ups FALSE -3 Int32
18-32 Analog Input X42/5 0 N/A All set-ups FALSE -3 Int32
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
180 MG16H102 - VLT
®
is a registered Danfoss trademark
44

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals