Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
16-61 Terminal 53 Switch Setting [0] Current All set-ups FALSE - Uint8
16-62 Analog Input 53 0 N/A All set-ups FALSE -3 Int32
16-63 Terminal 54 Switch Setting [0] Current All set-ups FALSE - Uint8
16-64 Analog Input 54 0 N/A All set-ups FALSE -3 Int32
16-65 Analog Output 42 [mA] 0 N/A All set-ups FALSE -3 Int16
16-66 Digital Output [bin] 0 N/A All set-ups FALSE 0 Int16
16-67 Pulse Input #29 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-68 Pulse Input #33 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-69 Pulse Output #27 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-70 Pulse Output #29 [Hz] 0 N/A All set-ups FALSE 0 Int32
16-71 Relay Output [bin] 0 N/A All set-ups FALSE 0 Int16
16-72 Counter A 0 N/A All set-ups TRUE 0 Int32
16-73 Counter B 0 N/A All set-ups TRUE 0 Int32
16-75 Analog In X30/11 0 N/A All set-ups FALSE -3 Int32
16-76 Analog In X30/12 0 N/A All set-ups FALSE -3 Int32
16-77 Analog Out X30/8 [mA] 0 N/A All set-ups FALSE -3 Int16
16-8* Fieldbus & FC Port
16-80 Fieldbus CTW 1 0 N/A All set-ups FALSE 0 V2
16-82 Fieldbus REF 1 0 N/A All set-ups FALSE 0 N2
16-84 Comm. Option STW 0 N/A All set-ups FALSE 0 V2
16-85 FC Port CTW 1 0 N/A All set-ups FALSE 0 V2
16-86 FC Port REF 1 0 N/A All set-ups FALSE 0 N2
16-9* Diagnosis Readouts
16-90 Alarm Word 0 N/A All set-ups FALSE 0 Uint32
16-91 Alarm Word 2 0 N/A All set-ups FALSE 0 Uint32
16-92 Warning Word 0 N/A All set-ups FALSE 0 Uint32
16-93 Warning Word 2 0 N/A All set-ups FALSE 0 Uint32
16-94 Ext. Status Word 0 N/A All set-ups FALSE 0 Uint32
16-95 Ext. Status Word 2 0 N/A All set-ups FALSE 0 Uint32
16-96 Maintenance Word 0 N/A All set-ups FALSE 0 Uint32
Table 4.15
4.1.15 18-** Info & Readouts
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
18-0* Maintenance Log
18-00 Maintenance Log: Item 0 N/A All set-ups FALSE 0 Uint8
18-01 Maintenance Log: Action 0 N/A All set-ups FALSE 0 Uint8
18-02 Maintenance Log: Time 0 s All set-ups FALSE 0 Uint32
18-03 Maintenance Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-1* Fire Mode Log
18-10 FireMode Log:Event 0 N/A All set-ups FALSE 0 Uint8
18-11 Fire Mode Log: Time 0 s All set-ups FALSE 0 Uint32
18-12 Fire Mode Log: Date and Time ExpressionLimit All set-ups FALSE 0 TimeOfDay
18-3* Inputs & Outputs
18-30 Analog Input X42/1 0 N/A All set-ups FALSE -3 Int32
18-31 Analog Input X42/3 0 N/A All set-ups FALSE -3 Int32
18-32 Analog Input X42/5 0 N/A All set-ups FALSE -3 Int32
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
180 MG16H102 - VLT
®
is a registered Danfoss trademark
44