Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
15-92 Defined Parameters 0 N/A All set-ups FALSE 0 Uint16
15-93 Modified Parameters 0 N/A All set-ups FALSE 0 Uint16
15-99 Parameter Metadata 0 N/A All set-ups FALSE 0 Uint16
Table 4.14
4.1.14 16-** Data Readouts
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
16-0* General Status
16-00 Control Word 0 N/A All set-ups FALSE 0 V2
16-01 Reference [Unit]
0 ReferenceFeed-
backUnit All set-ups FALSE -3 Int32
16-02 Reference [%] 0 % All set-ups FALSE -1 Int16
16-03 Status Word 0 N/A All set-ups FALSE 0 V2
16-05 Main Actual Value [%] 0 % All set-ups FALSE -2 N2
16-09 Custom Readout 0 CustomReadoutUnit All set-ups FALSE -2 Int32
16-1* Motor Status
16-10 Power [kW] 0 kW All set-ups FALSE 1 Int32
16-11 Power [hp] 0 hp All set-ups FALSE -2 Int32
16-12 Motor Voltage 0 V All set-ups FALSE -1 Uint16
16-13 Frequency 0 Hz All set-ups FALSE -1 Uint16
16-14 Motor current 0 A All set-ups FALSE -2 Int32
16-15 Frequency [%] 0 % All set-ups FALSE -2 N2
16-16 Torque [Nm] 0 Nm All set-ups FALSE -1 Int32
16-17 Speed [RPM] 0 RPM All set-ups FALSE 67 Int32
16-18 Motor Thermal 0 % All set-ups FALSE 0 Uint8
16-22 Torque [%] 0 % All set-ups FALSE 0 Int16
16-3* Drive Status
16-30 DC Link Voltage 0 V All set-ups FALSE 0 Uint16
16-32 Brake Energy /s 0 kW All set-ups FALSE 0 Uint32
16-33 Brake Energy /2 min 0 kW All set-ups FALSE 0 Uint32
16-34 Heatsink Temp. 0 °C All set-ups FALSE 100 Uint8
16-35 Inverter Thermal 0 % All set-ups FALSE 0 Uint8
16-36 Inv. Nom. Current ExpressionLimit All set-ups FALSE -2 Uint32
16-37 Inv. Max. Current ExpressionLimit All set-ups FALSE -2 Uint32
16-38 SL Controller State 0 N/A All set-ups FALSE 0 Uint8
16-39 Control Card Temp. 0 °C All set-ups FALSE 100 Uint8
16-40 Logging Buffer Full [0] No All set-ups TRUE - Uint8
16-41 LCP Bottom Statusline 0 N/A All set-ups TRUE 0 VisStr[50]
16-5* Ref. & Feedb.
16-50 External Reference 0 N/A All set-ups FALSE -1 Int16
16-52 Feedback[Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int32
16-53 Digi Pot Reference 0 N/A All set-ups FALSE -2 Int16
16-54 Feedback 1 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int32
16-55 Feedback 2 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int32
16-56 Feedback 3 [Unit] 0 ProcessCtrlUnit All set-ups FALSE -3 Int32
16-6* Inputs & Outputs
16-60 Digital Input 0 N/A All set-ups FALSE 0 Uint16
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
MG16H102 - VLT
®
is a registered Danfoss trademark
179
4 4

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals