25-34 Destage Function Time 15 s All set-ups TRUE 0 Uint16
25-4* Staging Settings
25-42 Staging Threshold ExpressionLimit All set-ups TRUE 0 Uint8
25-43 Destaging Threshold ExpressionLimit All set-ups TRUE 0 Uint8
25-44 Staging Speed [RPM] 0 RPM All set-ups TRUE 67 Uint16
25-45 Staging Speed [Hz] 0 Hz All set-ups TRUE -1 Uint16
25-46 Destaging Speed [RPM] 0 RPM All set-ups TRUE 67 Uint16
25-47 Destaging Speed [Hz] 0 Hz All set-ups TRUE -1 Uint16
25-8* Status
25-80 Pack Status 0 N/A All set-ups TRUE 0 VisStr[25]
25-81 Compressor Status 0 N/A All set-ups TRUE 0 VisStr[25]
25-82 Lead Compressor 0 N/A All set-ups TRUE 0 Uint8
25-83 Relay Status 0 N/A All set-ups TRUE 0 VisStr[4]
25-84 Compressor ON Time 0 h All set-ups TRUE 74 Uint32
25-85 Relay ON Time 0 h All set-ups TRUE 74 Uint32
25-86 Reset Relay Counters [0] Do not reset All set-ups TRUE - Uint8
25-87 Inverse Interlock 0 N/A All set-ups TRUE 0 Uint16
25-88 Pack capacity [%] 0 % All set-ups TRUE 0 Uint16
25-9* Service
25-90 Compressor Interlock [0] Off All set-ups TRUE - Uint8
25-91 Manual Alternation 0 N/A All set-ups TRUE 0 Uint8
Table 4.21
4.1.21 26-** Analog I/O Option MCB 109
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
26-0* Analog I/O Mode
26-00 Terminal X42/1 Mode [1] Voltage All set-ups TRUE - Uint8
26-01 Terminal X42/3 Mode [1] Voltage All set-ups TRUE - Uint8
26-02 Terminal X42/5 Mode [1] Voltage All set-ups TRUE - Uint8
26-1* Analog Input X42/1
26-10 Terminal X42/1 Low Voltage 0.07 V All set-ups TRUE -2 Int16
26-11 Terminal X42/1 High Voltage 10 V All set-ups TRUE -2 Int16
26-14
Term. X42/1 Low Ref./Feedb.
Value 0 N/A All set-ups TRUE -3 Int32
26-15
Term. X42/1 High Ref./Feedb.
Value 100 N/A All set-ups TRUE -3 Int32
26-16
Term. X42/1 Filter Time
Constant 0.001 s All set-ups TRUE -3 Uint16
26-17 Term. X42/1 Live Zero [1] Enabled All set-ups TRUE - Uint8
26-2* Analog Input X42/3
26-20 Terminal X42/3 Low Voltage 0.07 V All set-ups TRUE -2 Int16
26-21 Terminal X42/3 High Voltage 10 V All set-ups TRUE -2 Int16
26-24
Term. X42/3 Low Ref./Feedb.
Value 0 N/A All set-ups TRUE -3 Int32
26-25
Term. X42/3 High Ref./Feedb.
Value 100 N/A All set-ups TRUE -3 Int32
26-26
Term. X42/3 Filter Time
Constant 0.001 s All set-ups TRUE -3 Uint16
26-27 Term. X42/3 Live Zero [1] Enabled All set-ups TRUE - Uint8
26-3* Analog Input X42/5
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
186 MG16H102 - VLT
®
is a registered Danfoss trademark
44

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals