Danfoss VLT FC 103 Programming Guide

Danfoss VLT FC 103
203 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #188 background imageLoading...
Page #188 background image
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion
index
Type
26-30 Terminal X42/5 Low Voltage 0.07 V All set-ups TRUE -2 Int16
26-31 Terminal X42/5 High Voltage 10 V All set-ups TRUE -2 Int16
26-34
Term. X42/5 Low Ref./Feedb.
Value 0 N/A All set-ups TRUE -3 Int32
26-35
Term. X42/5 High Ref./Feedb.
Value 100 N/A All set-ups TRUE -3 Int32
26-36
Term. X42/5 Filter Time
Constant 0.001 s All set-ups TRUE -3 Uint16
26-37 Term. X42/5 Live Zero [1] Enabled All set-ups TRUE - Uint8
26-4* Analog Out X42/7
26-40 Terminal X42/7 Output [0] No operation All set-ups TRUE - Uint8
26-41 Terminal X42/7 Min. Scale 0 % All set-ups TRUE -2 Int16
26-42 Terminal X42/7 Max. Scale 100 % All set-ups TRUE -2 Int16
26-43 Terminal X42/7 Bus Control 0 % All set-ups TRUE -2 N2
26-44 Terminal X42/7 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
26-5* Analog Out X42/9
26-50 Terminal X42/9 Output [0] No operation All set-ups TRUE - Uint8
26-51 Terminal X42/9 Min. Scale 0 % All set-ups TRUE -2 Int16
26-52 Terminal X42/9 Max. Scale 100 % All set-ups TRUE -2 Int16
26-53 Terminal X42/9 Bus Control 0 % All set-ups TRUE -2 N2
26-54 Terminal X42/9 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
26-6* Analog Out X42/11
26-60 Terminal X42/11 Output [0] No operation All set-ups TRUE - Uint8
26-61 Terminal X42/11 Min. Scale 0 % All set-ups TRUE -2 Int16
26-62 Terminal X42/11 Max. Scale 100 % All set-ups TRUE -2 Int16
26-63 Terminal X42/11 Bus Control 0 % All set-ups TRUE -2 N2
26-64 Terminal X42/11 Timeout Preset 0 % 1 set-up TRUE -2 Uint16
Table 4.22
4.1.22 28-** Compressor Functions
Par. No. # Parameter description Default value 4-set-up Change
during
operation
Conver-
sion index
Type
28-2* Discharge Temperature Monitor
28-20 Temperature Source [0] None All set-ups FALSE - Uint8
28-21 Temperature Unit [60] °C All set-ups FALSE - Uint8
28-24 Warning Level 130 N/A All set-ups FALSE 0 Uint16
28-25 Warning Action [1] Decrease cooling All set-ups FALSE - Uint8
28-26 Emergency Level 145 N/A All set-ups FALSE 0 Uint16
28-27 Discharge Temperature 0 DTM_ReadoutUnit All set-ups TRUE 0 Int32
28-7* Day/Night Settings
28-71 Day/Night Bus Indicator [0] Day All set-ups TRUE - Uint8
28-72 Enable Day/Night Via Bus [0] Disabled All set-ups TRUE - Uint8
28-73 Night Setback
0 ReferenceFeed-
backUnit All set-ups TRUE -3 Int32
28-74 Night Speed Drop [RPM] ExpressionLimit All set-ups TRUE 67 Uint16
28-75 Night Speed Drop Override 0 N/A All set-ups TRUE -3 Int32
28-76 Night Speed Drop [Hz] ExpressionLimit All set-ups TRUE -1 Uint16
28-8* P0 Optimization
Parameter Lists
VLT
®
Refrigeration Drive Programming Guide
MG16H102 - VLT
®
is a registered Danfoss trademark
187
4 4

Table of Contents

Other manuals for Danfoss VLT FC 103

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Danfoss VLT FC 103 and is the answer not in the manual?

Danfoss VLT FC 103 Specifications

General IconGeneral
BrandDanfoss
ModelVLT FC 103
CategoryDC Drives
LanguageEnglish

Related product manuals