REFERENCES
157
5.11 C-GRYPHON™ CONFIGURATION
Battery selection is required only when the Gryphon™ M reader has an Alkaline
battery and you want to use C-Gryphon™ either for serial configuration, software
upgrades or to hold Gryphon™ M. Since this type of battery must not be charged it is
necessary to disable the C-Gryphon™ charge function by following the procedure:
With the Gryphon™ M read the following code:
1.
Alkaline
Ì$+RN4$-]Î
The green LED on the Gryphon™ M will blink, signaling the reader has
accepted the command.
2.
Place the reader onto the charger within 10 seconds. The green LED turns
off and a short beep is emitted
To enable the charge function repeat step 1 and 2 substituting the "Alkaline" code
with the following one:
NiMh/NiCd
Ì$+RN6$-gÎ
CAUTION
Attempts to charge Alkaline batteries could cause leakage of liquid,
generation of heat or, in extreme cases, explosion. If using Alkaline
batteries, carefully follow the procedure above to avoid damage.

Table of Contents

Other manuals for Datalogic GRYPHON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic GRYPHON and is the answer not in the manual?

Datalogic GRYPHON Specifications

General IconGeneral
BrandDatalogic
ModelGRYPHON
CategoryBarcode Reader
LanguageEnglish

Related product manuals