EasyManuals Logo
Home>Datalogic>Barcode Reader>GRYPHON

Datalogic GRYPHON User Manual

Datalogic GRYPHON
192 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #169 background imageLoading...
Page #169 background image
TECHNICAL FEATURES
161
6.3 OM-GRYPHON™ / C-GRYPHON™
OM-Gryphon™ C-Gryphon™
Electrical and General Features
Supply Voltage 9 to 28 Vdc
Power Consumption (max) 8 W (charging) *
Indicators Battery Charging LED (red)
Charge completed LED (green)
Power/Data LED (yellow)
Recharge Time
NiMh / NiCd batteries
From 3 to 5 hours
Host Interfaces
RS232 150 to 38400 baud 9600 baud
WEDGE
IBM AT or PS/2, XT, PC Notebook,
IBM SURE1, IBM 3153, 31xx, 32xx,
34xx, 37xx terminals, Wyse
terminals, Digital VT terminals,
Apple ADB Bus supported
Not supported
PEN Emulation
Selectable minimum pulse from 200 μS to 1.2 mS
Environmental Features
Working Temperature
0° to +40 °C / +32° to +104 °F
Storage Temperature -20° to +70 °C / -4° to +158 °F
Humidity 90% non condensing
Protection IP30
Mechanical Features
Weight (without cable) about 250 g. / 8.81 oz.
Dimensions 208 x 107 x 55.5 mm / 8.1 x 4.2 x 2.18 in
Material ABS
* Having a switching regulator inside, the OM-Gryphon™ and C-Gryphon™ draw the
same power, regardless of the supply voltage. i.e. as the input voltage increases
the current drawn decreases.

Table of Contents

Other manuals for Datalogic GRYPHON

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic GRYPHON and is the answer not in the manual?

Datalogic GRYPHON Specifications

General IconGeneral
BrandDatalogic
ModelGRYPHON
CategoryBarcode Reader
LanguageEnglish

Related product manuals