CUSTOMIZING CONFIGURATION SETTINGS
PRODUCT REFERENCE GUIDE
15
CUSTOMIZING CONFIGURATION SETTINGS
Using the Programming Bar Codes
This manual contains feature descriptions and bar codes which allow you to reconfigure
your reader. Some programming bar code labels, like
Resetting the Product Configuration
to Defaults, starting on page 16
, require only the scan of that single label to enact the
change.
Most of the programming labels in this manual, however, require the reader to be
placed in Programming Mode prior to scanning them. Scan an ENTER/EXIT bar code
once to enter Programming Mode. Once the reader is in Programming Mode, you can
scan a number of parameter settings before scanning the ENTER/EXIT bar code a second
time, which will then accept your changes, exit Programming Mode and return the
reader to normal operation.
Datalogic Aladdin™ Utility
Programming can alternatively be performed using the Datalogic Aladdin™ Configura-
tion application which is available for free download from the Datalogic website listed
on the back cover of this manual. This multi-platform utility program allows device con-
figuration using a PC. It communicates to the device using a serial or USB cable and can
also create configuration bar codes to print.
Datalogic Aladdin™ is a multi-platform utility program providing a quick and user-
friendly configuration method via the RS-232/USB-COM interface. The Aladdin utility is
available on the Datalogic website. Aladdin allows you to program the reader by select-
ing configuration commands through a user-friendly graphical interface running on a
PC. These commands are sent to the reader over the selected communication interface,
or they can be printed as bar codes to be scanned.
Aladdin also provides the ability to perform a software upgrade for the connected
device (see the Datalogic Aladdin™ Help On-Line for more details).
Interface Settings
The reader is typically factory-configured with a set of default features standard to the
interface type you ordered. See
Appendix B, Standard Defaults.
Global Interface Features, starting on
page 20 provides settings configurable by all inter-
face types. If your installation requires you to further customize your reader, you can
select other options through use of the instructions and programming bar codes avail-
able in the appropriate section for your interface.
•"
RS-232 INTERFACE" on page 21
•"RS-232/USB-COM Interfaces" on page 26
RS232 OPOS on page 12
USB Composite (COM + Keyboard) on page 12
•KEYBOARD INTERFACE on page 34
USB-OEM INTERFACE on page 63
NOTE: There are some exceptions to the typical programming sequence
described above. Please read the description and setting instructions care-
fully when configuring each given programmable feature.

Table of Contents

Other manuals for Datalogic QuickScan QD2590

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic QuickScan QD2590 and is the answer not in the manual?

Datalogic QuickScan QD2590 Specifications

General IconGeneral
TypeHandheld bar code reader
Sensor type-
Scanner type1D/2D
Scanner resolution0.17 mm
Tilt reading angle0 - 360 °
Pitch reading angle0 - 65 °
Light levels (direct sunlight)0 - 100000 lx
Linear (1D) barcodes supportedCPC Binary, Codabar, Codabar 125, Code 11, Code 128, Code 128A, Code 128B, Code 128C, Code 25 (IR 2 of 5), Code 25 (non-IR 2 of 5), Code 3 of 9, Code 32, Code 39, Code 93, DUN 14, DataBar14, Discrete 2 of 5, EAN 128, EAN 2, EAN 5, EAN-13, EAN-8, Facing Identification Mark, GS1 DataBar, GS1 DataBar Expanded, GS1 DataBar Omnidirectional, GS1 Databar Limited, GS1-128 (UCC/EAN-128), HIBC, IATA, ISBN, ISSN, ITF-14, ITF-6, Industrial 2 of 5, Intelligent Mail, Interleaved 2 of 5, JAN, Latent image, MSI, Matrix 2 of 5, PDF417, PLANET, POSTNET, Pharmacode, Plessey, PostBar, RM4SCC / KIX, S-Code, Telepen, Trioptic, U.P.C., UPC-A, UPC-E
Optical sensor resolution (W x H)1280 x 800 pixels
2D (matrix & stacked) barcodes supportedAztec Code, Data Matrix, Dot Code A, MaxiCode, Micro QR Code, QR Code
Cable length2 m
Standard interfacesUSB
Connectivity technologyWired
Product colorBlack
Image formats supportedBMP, JPEG, TIFF
International Protection (IP) codeIP52
Input voltage5 V
Power consumption450 mA
Cables includedUSB Type-C
Storage temperature (T-T)-40 - 70 °C
Operating temperature (T-T)0 - 50 °C
Operating relative humidity (H-H)0 - 95 %
Sustainability certificatesRoHS
MaterialPolyvinyl chloride (PVC)
Connector 1USB C
Product typeUSB cable
Connector genderMale/Male
Brand compatibilityDatalogic
Connector 1 form factorStraight
Harmonized System (HS) code84733020
Weight and Dimensions IconWeight and Dimensions
Depth126 mm
Width148 mm
Height68 mm
Weight145 g

Related product manuals