EasyManuals Logo

Dell EMC PowerEdge R350 Service Manual

Dell EMC PowerEdge R350
106 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #20 background imageLoading...
Page #20 background image
Table 8. Configuration validation error (continued)
Error Description Possible cause and
recommendations
Example
missing element (cable,
risers, etc).
Comm Error A configuration element is not responding
to iDRAC using the management interface
while running an inventory check.
System management
sideband communication
Comm Error: Backplane 2
Unplug AC Power, reseat
the element and replace
the element if the problem
persists.
Error messages
This section describes the error messages displayed on the screen during POST or captured in the system event log (SEL)/
LifeCycle (LC) log.
Table 9. Error message HWC8010
Error code HWC8010
Message The System Configuration Check operation resulted in the following issue involving the indicated
component type
Arguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other components
Detailed Description The issue identified in the message is observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Category System Health (HWC = Hardware Config)
Severity Critical
Trap/EventID 2329
Table 10. Error message HWC8011
Error code HWC8011
Message The System Configuration Check operation resulted in multiple issues involving the indicated component
type
Arguments Riser, floating card (fPERClike BOSS), backplane, processor, cable, or other components
Detailed Description Multiple issues are observed in the System Configuration Check operation.
Recommended
Response Action
Do the following and retry the operation:
1. Disconnect the input power.
2. Check for proper cable connection and component placement. If the issue persists, contact the
service provider.
Category System Health (HWC = Hardware Config)
Severity Critical
20 Minimum to POST and system management configuration validation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC PowerEdge R350 and is the answer not in the manual?

Dell EMC PowerEdge R350 Specifications

General IconGeneral
Chassis typeRack (1U)
Product colorBlack
Rack mountingYes
Memory slots4x DIMM
Memory ranking1
Internal memory8 GB
Memory clock speed3200 MHz
Buffered memory typeUnregistered (unbuffered)
Internal memory typeDDR4-SDRAM
Maximum internal memory64 GB
Operating system installedNo
Compatible operating systemsCanonical Ubuntu Server LTS Citrix Hypervisor Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Server
USB 2.0 ports quantity2
Operating altitude0 - 3048 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 65 °C
Storage relative humidity (H-H)5 - 95 %
Processor cache8 MB
Processor modelE-2334
Processor frequency3.4 GHz
Processor manufacturerIntel
Processor boost frequency4.8 GHz
On-board graphics card-
HDD size3.5 \
HDD speed7200 RPM
HDD interfaceSATA III
Total storage capacity4000 GB
Maximum storage capacity- TB
Supported RAID controllersPERC H345
Power supply600 W
Power cable length3 m
Power cable current15 A
Power cable connector 1C13 coupler
Power supply input voltage125 V
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeGigabit Ethernet
Weight and Dimensions IconWeight and Dimensions
Width- mm
Height42.8 mm