Table 31. DC PSU status indicator codes (continued)
Power indicator codes Condition
same power rating. This results in a PSU mismatch
condition, or failure to power on the system.
CAUTION: If two PSUs are used, they must be of
the same type and have the same maximum output
power.
CAUTION: When correcting a PSU mismatch, replace
the PSU with the blinking indicator. Swapping the
PSU to make a matched pair can result in an error
condition and an unexpected system shutdown. To
change from a High Output configuration to a Low
Output configuration or conversely, you must power
off the system.
CAUTION: Combining AC and DC PSUs is not
supported.
Drive indicator codes
The LEDs on the drive carrier indicate the state of each drive. Each drive carrier has two LEDs: an activity LED (green) and a
status LED (bicolor, green/amber). The activity LED blinks whenever the drive is accessed.
Figure 89. Drive indicators
1. Drive activity LED indicator
2. Drive status LED indicator
3. Drive capacity label
NOTE: If the drive is in the Advanced Host Controller Interface (AHCI) mode, the status LED indicator does not power on.
NOTE: Drive status indicator behavior is managed by Storage Spaces Direct. Not all drive status indicators may be used.
Table 32. Drive indicator codes
Drive status indicator code Condition
Blinks green twice per second Indicates that the drive is being identified or preparing for removal.
Off Indicates that the drive is ready for removal.
NOTE: The drive status indicator remains off until all drives are
initialized after the system is powered on. Drives are not ready
for removal during this time.
Blinks green, amber, and then powers off Indicates that there is an unexpected drive failure.
Blinks amber four times per second Indicates that the drive has failed.
Blinks green slowly Indicates that the drive is rebuilding.
Solid green Indicates that the drive is online.
System diagnostics and indicator codes 99

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell EMC PowerEdge R350 and is the answer not in the manual?

Dell EMC PowerEdge R350 Specifications

General IconGeneral
Chassis typeRack (1U)
Product colorBlack
Rack mountingYes
Memory slots4x DIMM
Memory ranking1
Internal memory8 GB
Memory clock speed3200 MHz
Buffered memory typeUnregistered (unbuffered)
Internal memory typeDDR4-SDRAM
Maximum internal memory64 GB
Operating system installedNo
Compatible operating systemsCanonical Ubuntu Server LTS Citrix Hypervisor Microsoft Windows Server with Hyper-V Red Hat Enterprise Linux SUSE Linux Enterprise Server
USB 2.0 ports quantity2
Operating altitude0 - 3048 m
Non-operating altitude0 - 12000 m
Storage temperature (T-T)-40 - 65 °C
Storage relative humidity (H-H)5 - 95 %
Processor cache8 MB
Processor modelE-2334
Processor frequency3.4 GHz
Processor manufacturerIntel
Processor boost frequency4.8 GHz
On-board graphics card-
HDD size3.5 \
HDD speed7200 RPM
HDD interfaceSATA III
Total storage capacity4000 GB
Maximum storage capacity- TB
Supported RAID controllersPERC H345
Power supply600 W
Power cable length3 m
Power cable current15 A
Power cable connector 1C13 coupler
Power supply input voltage125 V
Cabling technology10/100/1000Base-T(X)
Ethernet interface typeGigabit Ethernet
Weight and Dimensions IconWeight and Dimensions
Width- mm
Height42.8 mm

Related product manuals