Installing System Components 105
7
Reinstall the SAS controller daughter card. See "Installing a SAS Controller Daughter Card" on
page 70.
8
Reattach the SAS controller daughter card cables and the control panel cable. See "SAS and SAS RAID
Controller Daughter Card Cabling Guidelines" on page 72.
9
Reinstall the hard drives. See "Installing a Hot-Plug Hard Drive" on page 57.
NOTE: Reinstall the hard drives in the same drive bays from which they were removed.
10
If applicable, reconnect the internal tape drive. See "Removing and Installing an Internal SCSI Tape
Drive" on page 86.
11
If applicable, reconnect the diskette drive. See "Installing the Diskette Drive Into the System" on
page 84.
12
If applicable, reconnect the optical drive. See "Installing the Optical Drive" on page 82.
13
Close the system. See "Closing the System" on page 55.
Control Panel Assembly (Service-only Procedure)
NOTE: The control panel assembly consists of two separate modules—the display module and the control panel
circuit board. Use the following instructions to remove and install either module.
Removing the Control Panel Assembly
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. See your Product Information Guide for complete information about safety
precautions, working inside the computer, and protecting against electrostatic discharge.
1
If applicable, remove the bezel. See "Removing the Front Bezel" on page 53.
2
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet and
peripherals.
3
Open the system. See "Opening the System" on page 54.
4
Disconnect the control panel cable at back of the control panel board. See Figure 3-35.
NOTICE: Do not pull on the cable to unseat the connector. Doing so can damage the cable.
a
Squeeze the metal tabs on the ends of the cable connector.
b
Gently work the connector out of the socket.
5
Disconnect the display module cable from the control panel board. See Figure 3-35.
6
Remove the three screws that secure the control panel board to the system chassis and remove the
board. See Figure 3-35.
7
Remove the display module:
a
Insert the end of paper clip into the hole on the right side of the display module and gently pry off
the label.
Book.book Page 105 Friday, February 3, 2006 11:09 AM

Table of Contents

Other manuals for Dell PowerEdge 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2950 and is the answer not in the manual?

Dell PowerEdge 2950 Specifications

General IconGeneral
Tcase67 °C
Bus typeFSB
SteppingE0
FSB ParityYes
Processor codeSLBBP
Processor cache12 MB
Processor cores4
Processor modelE5405
System bus rate- GT/s
Processor seriesIntel Xeon 5400 Series
Processor socketLGA 771 (Socket J)
Processor codenameHarpertown
Motherboard chipsetIntel® 5000X
Processing Die size214 mm²
Processor frequency2 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)6
Number of Processing Die Transistors820 M
HDD size3.5 \
HDD capacity160 GB
HDD interfaceSerial ATA
Total storage capacity3320 GB
Maximum storage capacity6 TB
Graphics cardES1000
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed667 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory64 GB
Memory layout (slots x size)2 x 2 GB
Maximum graphics card memory16 MB
Networking featuresBroadcom NetXtreme IITM 5708 Gigabit5 Ethernet NIC
Supported network protocolsTOE (TCP/IP)
Other network protocols supportediSCSI Boot
PS/2 ports quantity0
USB 2.0 ports quantity5
Bundled softwareSymantec Backup ExecTM 12.5 Symantec Backup ExecTM System Recovery 8.5 CommVault 7.0 Vizioncore
Compatible operating systemsMicrosoft Windows Server 2008, Microsoft Windows Server 2003 Red Hat Linux Enterprise SUSE Linux Enterprise Server 10 x86-64 VMware ESX 3.5
Chassis typeRack (2U)
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)-40 - 65 %
Operating relative humidity (H-H)20 - 80 %
CertificationFCC (U.S. only) Class A ICES (Canada) Class B CE Mark (EN 55022 Class B, EN55024, EN61000-3-2, EN61000-3-3) VCCI (Japan) Class B BSMI (Taiwan) Class A C-Tick (Australia/New Zealand) Class B SABS (South Africa) Class B CCC (China) Class B MIC (Korea) Class B UL 60950 CAN/CSA C22.2 No. 60950 EN 60950 IEC 60950
Processor ARK ID33079
Weight and Dimensions IconWeight and Dimensions
Depth744 mm
Width444.3 mm
Height86.4 mm
Weight23000 g