EasyManuals Logo
Home>Dell>Server>PowerEdge 2950

Dell PowerEdge 2950 User Manual

Dell PowerEdge 2950
182 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #121 background imageLoading...
Page #121 background image
Troubleshooting Your System 121
3
Enter the System Setup program and check the system memory setting. See "Entering the System
Setup Program" on page 37.
If the amount of memory installed matches the system memory setting, go to step 11.
4
Remove the bezel. See "Front Bezel" on page 53.
5
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
6
Open the system. See "Opening and Closing the System" on page 54.
7
Reseat the memory modules in their sockets. See "Installing Memory Modules" on page 90.
8
Close the system. See "Opening and Closing the System" on page 54.
9
Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
10
Enter the System Setup program and check the system memory setting. See "Using the System Setup
Program" on page 37.
If the amount of memory installed does not match the system memory setting, then perform the
following steps:
a
Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
b
Open the system. See "Opening and Closing the System" on page 54.
NOTE: Several configurations for memory modules exist; see "General Memory Module Installation
Guidelines" on page 89.
c
Swap the memory module in socket 1 with another of the same capacity. See "Installing Memory
Modules" on page 90.
d
Close the system. See "Opening and Closing the System" on page 54.
e
Reconnect the system to its electrical outlet, and turn on the system and attached peripherals.
f
As the system boots, observe the monitor screen and the indicators on the keyboard.
11
Perform the following steps:
a
Turn off the system and attached peripherals, and disconnect the system from its electrical outlet.
b
Open the system. See "Opening and Closing the System" on page 54.
c
Perform step c through step f in step 10 for each memory module installed.
If the problem persists, see "Getting Help" on page 147.
Troubleshooting a Diskette Drive
Problem
Error message indicates a diskette drive problem.
Book.book Page 121 Friday, February 3, 2006 11:09 AM

Table of Contents

Other manuals for Dell PowerEdge 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2950 and is the answer not in the manual?

Dell PowerEdge 2950 Specifications

General IconGeneral
Tcase67 °C
Bus typeFSB
SteppingE0
FSB ParityYes
Processor codeSLBBP
Processor cache12 MB
Processor cores4
Processor modelE5405
System bus rate- GT/s
Processor seriesIntel Xeon 5400 Series
Processor socketLGA 771 (Socket J)
Processor codenameHarpertown
Motherboard chipsetIntel® 5000X
Processing Die size214 mm²
Processor frequency2 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)6
Number of Processing Die Transistors820 M
HDD size3.5 \
HDD capacity160 GB
HDD interfaceSerial ATA
Total storage capacity3320 GB
Maximum storage capacity6 TB
Graphics cardES1000
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed667 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory64 GB
Memory layout (slots x size)2 x 2 GB
Maximum graphics card memory16 MB
Networking featuresBroadcom NetXtreme IITM 5708 Gigabit5 Ethernet NIC
Supported network protocolsTOE (TCP/IP)
Other network protocols supportediSCSI Boot
PS/2 ports quantity0
USB 2.0 ports quantity5
Bundled softwareSymantec Backup ExecTM 12.5 Symantec Backup ExecTM System Recovery 8.5 CommVault 7.0 Vizioncore
Compatible operating systemsMicrosoft Windows Server 2008, Microsoft Windows Server 2003 Red Hat Linux Enterprise SUSE Linux Enterprise Server 10 x86-64 VMware ESX 3.5
Chassis typeRack (2U)
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)-40 - 65 %
Operating relative humidity (H-H)20 - 80 %
CertificationFCC (U.S. only) Class A ICES (Canada) Class B CE Mark (EN 55022 Class B, EN55024, EN61000-3-2, EN61000-3-3) VCCI (Japan) Class B BSMI (Taiwan) Class A C-Tick (Australia/New Zealand) Class B SABS (South Africa) Class B CCC (China) Class B MIC (Korea) Class B UL 60950 CAN/CSA C22.2 No. 60950 EN 60950 IEC 60950
Processor ARK ID33079
Weight and Dimensions IconWeight and Dimensions
Depth744 mm
Width444.3 mm
Height86.4 mm
Weight23000 g

Related product manuals