120 Troubleshooting Your System
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
Run the appropriate diagnostic test. See "Using Server Administrator Diagnostics" on page 131.
2
Open the system. See "Opening and Closing the System" on page 54.
CAUTION: The cooling fans are hot-pluggable. To maintain proper cooling while the system is on, only replace
one fan at a time.
3
Locate the faulty fan indicated by the LCD display or diagnostic software. For the identification
number of each fan, see Figure 3-9.
4
Ensure that the faulty fan's power cable is firmly attached to the fan power connector. See "System
Fans" on page 65.
NOTE: Wait 30 seconds for the system to recognize the fan and determine whether it is working properly.
5
If the problem is not resolved, install a new fan. See "System Fans" on page 65.
If the replacement fan is working properly, close the system. See "Opening and Closing the System" on
page 54.
If the replacement fan does not operate, see "Getting Help" on page 147.
Troubleshooting System Memory
Problem
Faulty memory module.
Faulty system board.
Front-panel status LCD indicates a problem with system memory.
Action
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. Before performing any procedure, see your Product Information Guide for
complete information about safety precautions, working inside the computer and protecting against electrostatic
discharge.
1
Run the appropriate online diagnostic test. See "Using Server Administrator Diagnostics" on page 131.
2
Turn on the system and attached peripherals.
If an error message does not appear, continue to the next step.
If an error messages appears, go to step 11.
Book.book Page 120 Friday, February 3, 2006 11:09 AM

Table of Contents

Other manuals for Dell PowerEdge 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2950 and is the answer not in the manual?

Dell PowerEdge 2950 Specifications

General IconGeneral
Tcase67 °C
Bus typeFSB
SteppingE0
FSB ParityYes
Processor codeSLBBP
Processor cache12 MB
Processor cores4
Processor modelE5405
System bus rate- GT/s
Processor seriesIntel Xeon 5400 Series
Processor socketLGA 771 (Socket J)
Processor codenameHarpertown
Motherboard chipsetIntel® 5000X
Processing Die size214 mm²
Processor frequency2 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)6
Number of Processing Die Transistors820 M
HDD size3.5 \
HDD capacity160 GB
HDD interfaceSerial ATA
Total storage capacity3320 GB
Maximum storage capacity6 TB
Graphics cardES1000
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed667 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory64 GB
Memory layout (slots x size)2 x 2 GB
Maximum graphics card memory16 MB
Networking featuresBroadcom NetXtreme IITM 5708 Gigabit5 Ethernet NIC
Supported network protocolsTOE (TCP/IP)
Other network protocols supportediSCSI Boot
PS/2 ports quantity0
USB 2.0 ports quantity5
Bundled softwareSymantec Backup ExecTM 12.5 Symantec Backup ExecTM System Recovery 8.5 CommVault 7.0 Vizioncore
Compatible operating systemsMicrosoft Windows Server 2008, Microsoft Windows Server 2003 Red Hat Linux Enterprise SUSE Linux Enterprise Server 10 x86-64 VMware ESX 3.5
Chassis typeRack (2U)
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)-40 - 65 %
Operating relative humidity (H-H)20 - 80 %
CertificationFCC (U.S. only) Class A ICES (Canada) Class B CE Mark (EN 55022 Class B, EN55024, EN61000-3-2, EN61000-3-3) VCCI (Japan) Class B BSMI (Taiwan) Class A C-Tick (Australia/New Zealand) Class B SABS (South Africa) Class B CCC (China) Class B MIC (Korea) Class B UL 60950 CAN/CSA C22.2 No. 60950 EN 60950 IEC 60950
Processor ARK ID33079
Weight and Dimensions IconWeight and Dimensions
Depth744 mm
Width444.3 mm
Height86.4 mm
Weight23000 g

Related product manuals