Installing System Components 107
4
Connect the display module cable to the control panel board. See Figure 3-35.
5
Connect the control panel cable to the control panel board. See Figure 3-35.
6
Close the system. See "Closing the System" on page 55.
7
Reconnect the system to the power source and turn on the system and attached peripherals.
8
If applicable, install the bezel.
System Board (Service-only Procedure)
Removing the System Board
CAUTION: Only trained service technicians are authorized to remove the system cover and access any of the
components inside the system. See your Product Information Guide for complete information about safety
precautions, working inside the computer, and protecting against electrostatic discharge.
1
Turn off the system and attached peripherals, and disconnect the system from the electrical outlet.
2
Open the system. See"Opening the System" on page 54
3
If applicable, remove any expansion cards. See "Installing an Expansion Card" on page 77
4
Remove the expansion-card cage. See "Removing the Expansion-Card Cage" on page 78
5
Remove the cooling shroud. See "Removing the Cooling Shroud" on page 67.
6
Remove the fans. See "Removing a System Fan" on page 65.
7
Remove the fan bracket. See "Removing the Fan Bracket" on page 68
8
If applicable, remove the RAC card. See "Installing a RAC Card" on page 80
CAUTION: The DIMMs are hot to the touch for some time after the system has been powered down. Allow time
for the DIMMs to cool before handling them. Handle the DIMMs by the card edges and avoid touching the DIMM
components.
9
Remove the memory modules. See "Removing Memory Modules" on page 92.
NOTE: While removing the memory modules, record the memory module socket locations to ensure proper
installation.
10
Remove the heatsink(s) and microprocessor(s). See "Removing a Processor" on page 93.
11
Remove the TOE key, if present. See Figure 6-2 for the location of the TOE key.
12
Remove the sideplane. See "Removing the Sideplane Board" on page 101.
13
Remove the SAS backplane. See "Removing the SAS Backplane Board" on page 103.
14
Remove the system board:
a
Pull the system-board tray riser release pin. See Figure 3-36.
b
While pulling the release pin, slide the system-board tray toward the front of the chassis.
c
Lift up the system-board tray and remove it from the chassis.
Book.book Page 107 Friday, February 3, 2006 11:09 AM

Table of Contents

Other manuals for Dell PowerEdge 2950

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge 2950 and is the answer not in the manual?

Dell PowerEdge 2950 Specifications

General IconGeneral
Tcase67 °C
Bus typeFSB
SteppingE0
FSB ParityYes
Processor codeSLBBP
Processor cache12 MB
Processor cores4
Processor modelE5405
System bus rate- GT/s
Processor seriesIntel Xeon 5400 Series
Processor socketLGA 771 (Socket J)
Processor codenameHarpertown
Motherboard chipsetIntel® 5000X
Processing Die size214 mm²
Processor frequency2 GHz
Processor cache typeL2
Processor lithography45 nm
Processor manufacturerIntel
Processor package size37.5 x 37.5 mm
Processor front side bus1333 MHz
Processor operating modes64-bit
ECC supported by processorNo
Thermal Design Power (TDP)80 W
Number of processors installed1
CPU multiplier (bus/core ratio)6
Number of Processing Die Transistors820 M
HDD size3.5 \
HDD capacity160 GB
HDD interfaceSerial ATA
Total storage capacity3320 GB
Maximum storage capacity6 TB
Graphics cardES1000
Memory slots8x DIMM
Internal memory4 GB
Memory clock speed667 MHz
Internal memory typeDDR2-SDRAM
Maximum internal memory64 GB
Memory layout (slots x size)2 x 2 GB
Maximum graphics card memory16 MB
Networking featuresBroadcom NetXtreme IITM 5708 Gigabit5 Ethernet NIC
Supported network protocolsTOE (TCP/IP)
Other network protocols supportediSCSI Boot
PS/2 ports quantity0
USB 2.0 ports quantity5
Bundled softwareSymantec Backup ExecTM 12.5 Symantec Backup ExecTM System Recovery 8.5 CommVault 7.0 Vizioncore
Compatible operating systemsMicrosoft Windows Server 2008, Microsoft Windows Server 2003 Red Hat Linux Enterprise SUSE Linux Enterprise Server 10 x86-64 VMware ESX 3.5
Chassis typeRack (2U)
Storage temperature (T-T)-40 - 65 °C
Operating temperature (T-T)10 - 35 °C
Storage relative humidity (H-H)-40 - 65 %
Operating relative humidity (H-H)20 - 80 %
CertificationFCC (U.S. only) Class A ICES (Canada) Class B CE Mark (EN 55022 Class B, EN55024, EN61000-3-2, EN61000-3-3) VCCI (Japan) Class B BSMI (Taiwan) Class A C-Tick (Australia/New Zealand) Class B SABS (South Africa) Class B CCC (China) Class B MIC (Korea) Class B UL 60950 CAN/CSA C22.2 No. 60950 EN 60950 IEC 60950
Processor ARK ID33079
Weight and Dimensions IconWeight and Dimensions
Depth744 mm
Width444.3 mm
Height86.4 mm
Weight23000 g