Page #110 background imageLoading...
Page #110 background image
Figure 112. Installing the front mounting front PERC module
Next steps
1. Reconnect all the required cables.
2. If removed, install the air shroud.
3. Install the drive backplane cover.
4. Follow the procedure listed in After working inside your system.
System battery
This is a service technician replaceable part only.
Replacing the system battery
Prerequisites
WARNING:
There is a danger of a new battery exploding if it is incorrectly installed. Replace the battery only
with the same or equivalent type recommended by the manufacturer. Discard used batteries according to the
manufacturer's instructions. See the Safety instructions that came with your system for more information.
1. Follow the safety guidelines listed in the Safety instructions.
2. Follow the procedure listed in Before working inside your system.
3. Remove the expansion card riser.
4. If applicable, disconnect the power or data cables from the expansion card(s).
Steps
1. To remove the battery:
a. Use a plastic scribe to pry out the system battery.
110
Installing and removing system components

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dell PowerEdge R650XS RD8NP and is the answer not in the manual?

Dell PowerEdge R650XS RD8NP Specifications

General IconGeneral
BrandDell
ModelPowerEdge R650XS RD8NP
CategoryServer
LanguageEnglish

Related product manuals