EasyManuals Logo
Home>Delta>Servo Drives>ASDA-B2 Series

Delta ASDA-B2 Series User Manual

Delta ASDA-B2 Series
345 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #90 background imageLoading...
Page #90 background image
ASDA-B2 Chapter 4 Panel Display and Operation
Revision May, 2018 4-9
4.4.3 Force DO Output
Enter into the Output Diagnosis Mode by the following settings. Set P2-08 to 406 and
enable the function of force DO output. Then, set the force DO output by binary method via
P4-06. When the setting value is 2, DO2 will be forced to enable. When the setting value is
5, DO1 and DO3 will be forced to enable. No data is retained in this mode. It returns to the
normal DO mode when re-power on the drive or set P2-08 to 400.
NOTE
P4-06 is displayed in hexadecimal format. Therefore, it will not show
the fifth 0.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta ASDA-B2 Series and is the answer not in the manual?

Delta ASDA-B2 Series Specifications

General IconGeneral
BrandDelta
ModelASDA-B2 Series
CategoryServo Drives
LanguageEnglish

Related product manuals