EasyManuals Logo
Home>Delta>Controller>DVP-EX2

Delta DVP-EX2 User Manual

Delta DVP-EX2
1006 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #882 background imageLoading...
Page #882 background image
6. Troubleshooting
6-9
6.3 Error Detection Devices
Error Check
Devices
Description Drop Latch
STOP

RUN RUN

STOP
M1067
Program execution error flag
None
Reset
Latch
M1068
Execution error latch flag
None
Latch
Latch
D1067
Algorithm error code
None
Reset
Latch
D1068
Step value of algorithm errors
None
Latch
Latch
Device D1067
Error Code
Description
0E18
BCD conversion error
0E19
Division error (divisor=0)
0E1A
Floating point exceeds the usage range
0E1B
The value of square root is negative
0E1C
Instructions FROM/TO communication error

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta DVP-EX2 and is the answer not in the manual?

Delta DVP-EX2 Specifications

General IconGeneral
BrandDelta
ModelDVP-EX2
CategoryController
LanguageEnglish

Related product manuals