2
VFD-B Series
DELTA ELECTRONICS, INC. ALL RIGHTS RESERVED
2-1
CHAPTER 2 STORAGE AND INSTALLATION
2.1 Storage
The AC drive should be kept in the shipping carton before installation. In order to retain the
warranty coverage, the AC drive should be stored properly when it is not to be used for an
extended period of time.
Ambient Conditions:
Operation
Air Temperature: -10
o
C to +40
o
C (14
o
F to 104
o
F) (UL & cUL);
+50
o
C (122
o
F) without dust cover.
Atmosphere pressure: 86 to 106 kPa
Installation Site Altitude: below 1000m
Vibration: Maximum 9.80 m/s
2
(1G) at less than 20Hz
Maximum 5.88 m/s
2
(0.6G) at 20Hz to 50Hz
Storage
Temperature: -20
o
C to +60
o
C (-4
o
F to 140
o
F)
Relative Humidity: Less than 90%, no condensation allowed
Atmosphere pressure: 86 to 106 kPa
Transportation
Temperature: -20
o
C to +60
o
C (-4
o
F to 140
o
F)
Relative Humidity: Less than 90%, no condensation allowed
Atmosphere pressure: 86 to 106 kPa
Vibration: Maximum 9.80 m/s
2
(1G) at less than 20Hz, Maximum 5.88
m/s
2
(0.6G) at 20Hz to 50Hz
Pollution Degree 2: good for a factory type environment.

Table of Contents

Other manuals for Delta VFD185B43A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD185B43A and is the answer not in the manual?

Delta VFD185B43A Specifications

General IconGeneral
BrandDelta
ModelVFD185B43A
CategoryDC Drives
LanguageEnglish

Related product manuals