CHAPTER 8 SUMMARY OF PARAMETER SETTINGS
îš•: The parameter can be set during operation. *: Twice the value for 460V class
Group 0: User Parameters
Parameter Explanation Settings
Factory
Setting
00-00 Identity Code of AC Drive Read-only ##
00-01 Rated Current Display Read-only ##.#
08: Keypad lock
00-02 Parameter Reset
10: Reset parameter to factory setting
00
00: F (setting frequency)
01: H (actual frequency)
02: U (user-defined unit)
03: Multi Function Display
00-03
Start-up Display Page
Selection îš•
04: FWD/REV
00
00: Display output current (A)
01: Display counter value (C)
02: Display process operation (1. tt)
03: Display DC-BUS voltage (U)
04: Display output voltage (E)
05: Output power factor angle (n.)
06: Display output power (kW)
07: Display actual motor speed (HU)
08: Display the estimative value of
the ration of torque (t)
09: Display PG numbers/10ms (G)
10: Display analog feedback signal
value (b)
11: Display AVI (U1.) (%)
12: Display ACI (U2.) (%)
00-04
Content of Multi Function
Display
13: Display AUI (U3.) (%)
00