23
【
When TOC is read
】
1
3
R E A D I N G
(
1
,
3
lit)
5.3 Error display
1
3
C D E X - X X
(
1
,
3
lit/X-XX:Errorcord
)
Error code
E1-00 Disc cannot be detected
E1-01 Tracking offset adjustment not possible
E1-02 Focus offset adjustment not possible
E2-00 Focus servo dropped during playback.
E2-01 Focus servo dropped during searching.
E2-03 Focus servo dropped during TOC reading.
E2-06 Focus servo dropped during manual search.
E2-10 Subcode can no longer be read during playback
E2-11 Subcode can no longer be read during searching
E2-12 Subcode can no longer be read during TOC reading
E2-14 Subcode cannot be read during pause
E2-15 Subcode cannot be read during manual search
E3-00 TOCcouldnotbereadwithinspeciedtime
E3-01 PVD/SVDanalysiscouldnotbecompletedwithinspeciedtime
E4-04 Search time out
E4-05 Error in communications with CD decoder
E5-00 Inner switch not on
E6-00 Inner switch not off
E9-00 Trayisnotopenedbythespeciedtime.
E9-01 Other error
【
Number of heat runs performed when error occurred
】
(1) Press the +/
9
button while the error is displayed.
(2) No. heat runs is displayed for 5 seconds, the error display reappears.
1
3
C D X X X X
(
1
,
3
lit/XXXX
:
Number of heat runs repeated when error occurred
)
【
Track no. and elapsed time when error occurred
】
(1) Press the
8
/ - button while the error is displayed.
(2) The track no. and time when the error occurred is displayed for 5 seconds, then error display reappears.
1
3
C D 0 1
Tr
m m : s s
(
1
,
3
lit / mm:ss
:
Number of heat runs repeated when error occurred
)