51
4. To remove the On/Off Switch and the Alarm Switch, use a pair of needle nose pliers and
grasp the switch at the base of the level screw bracket and gently wiggle it and pull
upward. (Note: if the bracket is bent, the switch will need to be replaced as the
levels will not be correct.)
Figure 9 6
5. Disconnect the red and brown wires from the On/Off switch.
6. Disconnect the yellow and blue wires from the Alarm Switch.
7. Remove the Phillips head screw and retaining washer that holds the Transponder Board
in place.