67
Control Housing Installation
1. Unhook the Control Housing from the Motor Housing.
2. Slide the Control Housing back onto the Motor Housing being sure not to pinch or crimp
any of the wires. Note: The air release plug must be removed to install the Control
Housing onto the Motor Housing.
3. Reinstall the three bolts and use three new Nyloc nuts to secure the Control Housing.
4. Perform the Control Cavity leak test as described in Chapter 13.
5. Apply Loctite 598 generously to the threads of the air release plug and install it. Smear
the excess 598 over the plug after it is installed (apply more 598 if necessary to cover
the plug).
Figure 10 6 Figure 10 7
Reinstall the Top Housing on the DR model as described in Chapter 8a.