- 25 -
5.2
Error codes and solutions
When the outboard is running in abnormal conditions or having malfunction,
a warning message will display with an error code. The table below will help
you get a solution.
Code
Description Solutions
E01 Motor Over
Voltage
Stop the motor and wait until the error message
disappears. If the problem still exists, contact
your dealer for repairing.
E02 Motor Over
Current
Disconnect the battery and check if the motor is
blocked. If not, continue driving at lower speed.
If this issue cannot be solved, please contact
ePropulsion service.
E03/
E04
Motor
Overheating
Wait a few minutes until the motor cools down
and the warning message disappears.
E05 Motor Under
voltage
Indicate the battery level is extremely low. The
outboard can probably be restarted at lower
speed after the message is dismissed.
E10 Motor Blocked Disconnect the battery and remove anything
that is blocking the motor. Make sure the
propeller can be rotated by hand smoothly.
E20 Battery
Communication
Fault
Turn off the motor and reconnect the battery
cable. If this issue cannot be solved, please
contact ePropulsion service.
E21 Motor
Communication
Fault
Turn off the motor and reconnect the battery
cable. If this issue cannot be solved please
contact ePropulsion service.
E30 Throttle
Calibration
Calibration process:
1. Press and hold “SELECT” button(≥10secs)