EPSON Stylus C110/C120/D120 Revision B
DISASSEMBLY/ASSEMBLY Disassembling Printer Mechanism 91
4.5.9 PF Scale
Part/Unit that should be removed before removing PF Scale
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor
Removal Procedure
1. Peel of the PF Scale that is secured with the double-sided tape (x1) from the Spur
Gear 32.4.
Figure 4-47. Removing PF Scale
4.5.10 PF Motor
Part/Unit that should be removed before removing PF Motor
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/PF
Encoder Sensor/PF Scale
Removal Procedure
1. Release the PF Motor connector cable from the notches (x2) of the Base Frame.
Figure 4-48. Removing PF Motor (1)
2. Remove the Grounding Spring from the PF Motor.
3. Remove the screws (x3) that secure the PF Motor, and remove it.
Figure 4-49. Removing PF Motor (2)
Pay attention to the following instructions.
Do not touch the PF Scale with bare hand.
Do not damage the PF Scale.
C.B.P. 3x8, F/Zn-3C (6±1kgfcm)
Grounding Spring
PF Motor
Guide Pin and Positioning Hole
1
2
C.B.S. 3x6, F/Zn-3C (8±1kgfcm)
3