EPSON Stylus C110/C120/D120 Revision B
DISASSEMBLY/ASSEMBLY Disassembling Printer Mechanism 93
4.5.11 CR Motor
Part/Unit that should be removed before removing CR Motor
Upper Housing/Lower Housing/Main Board Unit/Left Frame/Panel Unit/Front
Frame/Right Frame
Removal Procedure
1. Turn the Spur Gear 51.5 to release the Carriage Lock, and move the CR Unit to the
center of the printer.
(Refer to 4.5.2 Printhead Step1 (p83))
2. Release the CR Motor cable from the notches (x3) of the Base Frame and the
hooks (x3) of the Main Frame, and then pull out the cable through the hole of the
Base Frame.
Figure 4-53. Removing CR Motor (1)
3. Loosen the tension of the Timing Belt by pressing the Driven Pulley Holder in the
direction of the arrow as shown in the figure, and release the Timing Belt from the
pinion gear of the CR Motor.
4. Remove the screws (x2) that secure the CR Motor, and remove it.
Figure 4-54. Removing CR Motor (2)
Be careful not to damage the CR Motor cable when releasing the
cable from the hooks of the Main Frame.
After releasing the Timing Belt, temporarily secure the belt to the
Cartridge Cover with a tape or the like so as not to allow the grease
to come in contact with the Timing Belt. Contaminating the belt
with grease can result in malfunction of the printer.