AIR DISCHARGE FUNCTION
22
ADDITIONAL THERMOSTAT 14.2.
INSTALLATION
Switch the appliance o using the master switch positioned
on the rear of the stove.
Remove the plug from the socket.
Refer to the electrical layout to connect the two thermostat
cables onto the relative clamps positioned don the rear of the
machine, one is red and the other black (STBY clamp). The STBY
and AUX clamps can be noted in the diagram below. Every model
can have a dierent position of the relative clamps in the rear of
the machine. The image is given as an example.
gure 21
AIR DISCHARGE FUNCTION15.
The function allows to vent the air from the product. To activate the
procedure, press the
P1
and
P4
keys at the same time and
insert the password 77. Conrm using the
P5
key.