427-0089-00-12 Version 160 March 2019 11
This document does not contain any export-controlled information.
Camera Installation
As the diagram below indicates, be sure to allow adequate space for cable egress behind the gland.
This requirement may vary, depending on the installation. Maintain the bend radius per the
recommendation of the cable manufacturer. The typical cable bend radius is 50-75 mm (2-3 in).
1.3.7 Camera Mounting with Concealed Cable Wall Mount
The FC-Series camera can be secured to the optional Concealed Cable Wall Mount with four M5 x
0.8 threaded fasteners to the bottom of the camera. Use Loctite 222 low strength threadlocker for
the mount fasteners. Refer to Concealed Cable Mount Accessory, pg. 18 for additional information.
Figure 1-3: Rear Cable Bend Radius
Figure 1-4: FC-Series Installed with Concealed Cable Wall
Mount and Pole Adapter kit