EasyManuals Logo
Home>Garland>Oven>Mealstream CTM3

Garland Mealstream CTM3 User Manual

Garland Mealstream CTM3
56 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #48 background imageLoading...
Page #48 background image
Mealstream Ovens Pt. No. 32Z3403 Issue 16
Page 48
APPENDIX 3: TEMPERATURE SENSOR RESISTANCE DATA
Temp °F Temp °C Min. Rate
kȍ
Standard
Rate kȍ
Max. Rate
kȍ
212 100 11.490 13.060 14.810
302 150 2.803 3.161 3.434
392 200 0.950 1.000 1.050
482 250 0.3572 0.3865 0.4171
350 177 1.741
R(200)°C = 1 kȍ ±5%
Temperature Sensor Resistance
Note:
These resistances will only be apparent in a stable cavity temperature as the
sensor has a slow response time.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Garland Mealstream CTM3 and is the answer not in the manual?

Garland Mealstream CTM3 Specifications

General IconGeneral
BrandGarland
ModelMealstream CTM3
CategoryOven
LanguageEnglish

Related product manuals