EasyManuals Logo
Home>GE>Heat Pump>ASH220NCDWA

GE ASH220NCDWA User Manual

GE ASH220NCDWA
130 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #11 background imageLoading...
Page #11 background image
INTRODUCTION
ENGLISH
A-9
Functions and Control
Over-Temperature Heat Mode Indoor Coil
The over-temperature routine will protect the system from excessive high indoor coil temperature during heat mode operation.
The routine will initiate if the indoor coil temperature sensor reads temperatures in excess of 131F. Conditions that cause high
indoor coil temperature include indoor fan failure, dirty indoor coil and operating the system in heat mode when outdoor air
temperatures exceed operating limit. (Too warm outside)
Should this routine be initiated, the system will reduce compressor frequency until the indoor coil temperature reaches 117F.
Once this is achieved, the system will return to normal operation.
149°F
131°F
138°F
117°F
124°F

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE ASH220NCDWA and is the answer not in the manual?

GE ASH220NCDWA Specifications

General IconGeneral
BrandGE
ModelASH220NCDWA
CategoryHeat Pump
LanguageEnglish

Related product manuals