Table 4: Sensor group characteristics
Type
Name/application
Siren type
Dela
y
Restoral
Supervised
Active in
arming
levels
00 Fixed panic: 24-hour audible fixed emergency button. Intrusion I N Y 01234
01 Portable panic: 24-hour audible portable emergency
button.
Intrusion I N N 01234
02 Fixed panic: 24-hour silent fixed emergency button.
Status light will not blink.
Silent I N Y 01234
03 Portable panic: 24-hour silent portable emergency
buttons. Status light will not blink.
Silent I N N 01234
04 Fixed auxiliary: 24-hour auxiliary sensor. Emergency I N Y 01234
05 Fixed auxiliary: 24-hour emergency button. Siren shut
off confirms CS report.
Emergency I N Y 01234
06 Portable auxiliary: 24-hour portable auxiliary alert
button.
Emergency I N N 01234
07 Portable auxiliary 24-hour portable auxiliary button.
Siren shut off confirms CS report.
Emergency I N N 01234
08 Special intrusion: Such as gun cabinets and wall safes. Intrusion I Y Y 1234
09 Special intrusion: Such as gun cabinets and wall safes. Intrusion S Y Y 1234
10 Entry/exit delay: A delay that requires a standard delay
time. Chime.
Intrusion S Y Y 24
13 Instant perimeter: Exterior doors and windows. Chime. Intrusion I Y Y 24
14 Instant interior: Interior door. Intrusion F Y Y 234
15 Instant interior: Interior PIR motion sensor. Intrusion F Y Y 234
16 Instant interior: Interior door. Intrusion F Y Y 34
17 Instant interior: PIR motion sensor and sound sensor. Intrusion F N Y 34
18 Instant interior: Cross-zone PIR motion sensor. Intrusion F N Y 34
19 Delayed interior: Interior doors that initiate a delay
before going into alarm.
Intrusion S Y Y 34
20 Delayed interior: PIR motion sensor that initiates a delay
before going into alarm.
Intrusion S N Y 34
21 Local instant interior: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Intrusion I Y Y 1234
22 Local delayed interior: Same as group 21, plus
activation initiates a delay before going into alarm. No
report.
Intrusion S Y Y 1234
23 Local instant auxiliary: 24-hour local alarm zone
protecting anything that opens and closes. No report.
Emergency I Y Y 01234
6 Simon XT Installation Manual

Other manuals for GE SIMON XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE SIMON XT and is the answer not in the manual?

GE SIMON XT Specifications

General IconGeneral
BrandGE
ModelSIMON XT
CategorySecurity System
LanguageEnglish

Related product manuals