Function Default Description
Downloader
enable
On Enables programming of system options with downloader
software.
Sup protest Off Determines whether the panel protests arming if it has not received
a supervisory signal from any sensor 15 minutes before arming
(on), or not (off). This feature must be turned on for US installations.
Phone numbers
Table 12 below describes the Phone Numbers menu.
Table 12: Phone Numbers menu
Function Default Description
Phone #1 Blank
Phone #2 Blank
Phone #3 Blank
Phone #4 Blank
Lets you program up to a 26-digit central monitoring station
receiver/voice event notification phone number for monitored
systems. Phone digits can be 0 to 9, *, #, or a pause (P).
To delete the phone number, press Disarm while editing a phone
digit. To add a pause to the phone number, press Bypass. Pressing
OK is required if you enter fewer than 26 digits.
Downloader # Blank Lets you program up to a 26-digit phone number for the Enterprise
Downloader.
Phone options
Table 13 below describes the Phone Options menu.
Table 13: Phone Options menu
Function Default Description
Man phone test On Determines whether you can perform a manual communication
test to verify communication to a central station/voice dial (on), or
not (off). If you have all four phone numbers programmed, it should
send a test report to all four before showing that the test is okay.
FTC On Determines whether the panel and interior sirens sound trouble
beeps if it is unable to successfully send a report to a central
station (on), or not (off).
DTMF dial On Determines whether the panel uses DTMF (on) or pulse (off) for
dialing programmed phone numbers.
300 bps enabled On Determines whether the baud rate used by the panel for central
station communication is 300 bps (on), or 110 bps (off).
Simon XT Installation Manual 29

Other manuals for GE SIMON XT

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE SIMON XT and is the answer not in the manual?

GE SIMON XT Specifications

General IconGeneral
BrandGE
ModelSIMON XT
CategorySecurity System
LanguageEnglish

Related product manuals