Offsite phone operation
Test the system from a remote phone by calling the panel and using the commands
in Table 28 below.
Table 28: Phone commands
System function Phone command
Disarm 1
Arm doors/windows 2
Arm motion sensors 3
Arm doors/windows with no entry delay 2 2
Arm motion sensors with latchkey 3 3
Arm doors/windows and motion sensors 2 3
Arm doors/windows with no entry delay and
motion sensors with latchkey
2 2 3 3
Specific light on *, <unit number>
Specific light off #, <unit number>
All lights on * *
All lights off # #
System status 0
Audio verification 5 plus X (X= a command from Audio Verification
Set)
Terminate session 9
Central station communication
After performing sensor and communication tests, check that the system is reporting
alarms successfully to the central station.
Table 29 on page 48 provides a list of
sensor/user report codes.
To test communication with the central station:
1. Call the central station and tell the operator that you will be testing the system.
2. Arm the system.
3. Test each of the wireless panic buttons and trip at least one sensor of each type
(fire, intrusion, etc.) to verify that the appropriate alarms are working correctly.
4. When you finish testing the system, call the central station to verify that the
alarms were received.
Simon XT Installation Manual 47