Function Default Description
Low CPU battery On Determines whether the panel sends a low CPU battery report
to the central station when the panel backup battery voltage
drops.
Sen alarm restore Off Determines whether the panel reports sensor alarm restoral
(on), or not (off). Setting when restoral is reported:
1. Immediately after sensor is closed or restored after
dial delay
2. After siren timeout expires if sensor is restored
3. When system is disarmed if sensor is restored.
24-hour sensor
tamper
Off Determines whether the system (armed or disarmed) goes into
and reports an alarm anytime a sensor tamper switch is
tripped (on), or only when the system is armed and a tamper
switch of an armed sensor is tripped (off).
Supervisory tamper Off Determines whether the panel sends supervisory reports to a
central station as a tamper (on), or a supervisory (off).
This option is typically used only in Europe where a supervisory
condition is required to report as a tamper.
No usage Off Determines whether the panel sends a No Usage report to the
central station if the user has not operated the system before
the programmed time expires (on), or not (off). The timer starts
each time the system is disarmed.
This is a customer service feature that alerts the central station
if a customer is not using their security system. The service
provider can then contact the customer to find out why the
system is not being used, and help correct any problems for
the customer.
Swinger shutdown On Determines whether the panel prevents the same sensor from
activating an alarm more than once in a single period (on), or
not (off).
Swinger shutdown does not affect smoke and fire sensors.
Program report Off Determines whether the panel sends a report to the central
station anytime the programming mode is entered/exited (on),
or not at all (off). The panel sends a report whenever the dealer
(Utility 1) or installer (Utility 2) code is used to enter
programming mode and another report is sent when the
programming session ends.
Fire verify Off If this option is off, the panel immediately reports to the central
station when a smoke detector goes into alarm.
With this option on, if a single smoke detector goes into alarm,
the panel will not report for 60 seconds unless another smoke
detector goes into alarm. If the first smoke detector is cleared
of alarm within the first 60 seconds, not report will be sent to
the central station unless it or a second smoke detector goes
into alarm within the panel siren timeout period (5 minutes).
34 Simon XT Installation Manual