18 VDL200 • Quick installation guide - Specifications and connection
5 - Options
5.1 Optional external fuses
5.1.1 Network side fuses (F1)
The inverter must be fused upstream on the network side.
Use fast-acting fuses only.
Size
F1 - External network side fuses
DC link capacitor hours of
service life [h]
EUROPE AMERICA
Type Code Type Code
VDL200-...-4, 3ph
1040 > 15000 GRD2/20 F4D15 A70P20 S7G48
1055 > 15000 GRD2/25 F4D16 A70P25 S7G51
2075 > 15000 GRD3/35 F4D20 A70P40 S7G52
2110 > 15000 Z22GR40 F4M16 A70P40 S7G52
3150 > 15000 Z22GR63 F4M17 A70P60-4 S7I34
3185 > 15000 Z22GR80 F4M19 A70P80 S7G54
3220 > 15000 Z22GR80 F4M19 A70P80 S7G54
Technical data for fuses, including dimensions, weights, power leakage, fuse carriers etc. are reported in the corresponding manufacturers' data sheets:
GRD... (E27), S00... Jean Müller, Eltville
A70... Ferraz
5.2 Input chokes
The three-phase mains choke is strongly recommended in order to:
- limit the RMS input current of the VDL200 inverter.
- increase the life of intermediate circuit capacitors and reliability of input diodes.
- reduce mains harmonic content
 
In accordance with EN 12015 (THD values < 35%), provide the following:

5.2.1 AC input chokes
Size
Effective input current In
(@400V/50Hz, with AC input
chokes)
(A)
Model Code
Dimensions: W x H x d
mm [inches]
Weight
kg [lbs]
VDL200-...-4, 3ph
1040
9
LR3y-2040 S7AAG 120 x 125 x 65 [4.7 x 4.9 x 2.6] 2 [4.4]
1055
13.5
LR3y-2055 S7AB5 120 x 125 x 75 [4.7 x 4.9 x 2.6] 2.2 [4.4]
2075
18
LR3y-2075 S7AB6 150 x 155 x 79 [5.9 x 6.1 x 3.1] 4.9 [10.8]
2110 24 LR3y-3110 S7AB7 150 x 155 x 79 [5.9 x 6.1 x 3.1] 5 [11]
3150
32
LR3y-3150 S7AB8 150 x 169 x 85 [5.9 x 6.7 x 3.3] 5.5 [12.1]
3185
39
LR3y-3150 S7AB8 150 x 169 x 85 [5.9 x 6.7 x 3.3] 5.5 [12.1]
3220
44.5
LR3-022 S7FF4 180 x 182 x 130 [7.1 x 7.2 x 5.1] 7.8 [17.2]
5.2.2 DC input chokes
Size
Effective input current I
n
(with external DC chokes)
External DC chokes
@230V/50Hz @400V/50Hz
Rated
current
Overload
current
Model Code
Dimensions:
Width x Height x Depth
Weight
(A) (A) (Arms) (*) (Arms) mm [inches] kg [lbs]
1040 8 8 10 20 LDC-004 S7AI10 99 x 96 x 93 [3.90 x 3.78 x 3.66] 2.4 [5.3]
1055 12 12 16 31 LDC-005 S7AI11 125 x 112 x 98 [4.92 x 4.41 x 3.86] 4.1 [9.0]
2075 16 16 21 41 LDC-007 S7AI12 125 x 127 x 122 [4.92 x 5.00 x 4.80] 4.9 [10.8]
2110 21 21 28 54 LDC-011 S7AI13 125 x 127 x 142 [4.92 x 5.00 x 5.59] 6.6 [14.6]
3150 28 28 36 70 LDC-015 S7AI14 125 x 127 x 152 [4.92 x 5.00 x 5.98] 8 [17.6]
3185 34 34 45 90 LDC-022 S7AI15 155 x 160 x 148 [6.10 x 6.30 x 5.83] 8.5 [18.7]
3220 39.5 39.5 45 90 LDC-022 S7AI15 155 x 160 x 148 [6.10 x 6.30 x 5.83] 8.5 [18.7]

Table of Contents

Other manuals for gefran VDL200 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the gefran VDL200 Series and is the answer not in the manual?

gefran VDL200 Series Specifications

General IconGeneral
Brandgefran
ModelVDL200 Series
CategoryDC Drives
LanguageEnglish

Related product manuals