VDL200 • Quick installation guide - Specifications and connection 37
8.2 Navigating with the optional keypad
8.2.1
First level
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
23 ALARM LOG
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
01 MONITOR
02 DRIVE INFO
03 STARTUP WIZARD
04 DRIVE CONFIG
05 LIFT
First level Second level
01 MONITOR
02 DRIVE INFO
03
STARTUP WIZARD
04
DRIVE CONFIG
05 LIFT
05.1 SPEED'
05.2 RAMPS
05.3 LIFT SEQUENCES
05.4 MECHANICAL DATA
05.5 DISTANCE
Note! This example is only visible in Expert mode.
8.2.2 Display of a parameter
j
14 MOTOR DATA
k
01/26 PAR: 2000
l
Rated voltage
400 V
o
m
Def: 400
(1) Reference to the menu where the parameter is to be found (in this case menu 14 - MOTOR DATA)
(2) Position of the parameter in the menu structure (01)
(3) Description of the parameter (Rated voltage)
(4) Depends on the type of parameter:
• Numeric parameter: displays the numeric value of the parameter, in the format required, and unit of measurement.
• Binary selection: the parameter may assume only 2 states, indicated as On - or 0 - 1.
• LINK type parameter: displays the description of the parameter set from the selection list.
• ENUM type parameter: displays the description of the selection
• Command: displays the method of execution of the command
(5) Parameter number
(6) In this position, the following may be displayed:
• Numeric parameter: displays the default, minimum and maximum values of the parameter. These values are dis-
• LINK type parameter: displays the number (PAR) of the parameter set.
• ENUM type parameter: displays the numeric value corresponding to the current selection.
• Command: in the case of an error in the command, indicates that ESC must be pressed to terminate the com-
mand.
• Messages and error conditions:
Param read only attempt to modify a read-only parameter
Password active the parameter protection password is active
Drive enabled
Input value too high the value entered too high
Input value too low the value entered too low
Out of range attempt to insert a value outside the min. and max. limits