SPECIFICATIONS
GEM-P9600
Panel Dimensions: 12.375" x 13.875" x 3.55" (H x W x D)
Operating Temperature: 0-49°C (32-120°F)
Input Power: 16.5VAC via CLASS 2 Plug-In 40VA or 50VA Transformer
Loop Voltage: 10-13VDC
Loop Current: 2.4mA with 2.2K Ohm end-of-line resistor (Model EOL2.2K); 5mA for 2-wire smoke-detector zones; 1.4
mA using a 3.9K Ohm resistor (Model EOL 3.9K) with Zone Doubling
Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-detector zones
Relay Outputs (Burglary; Reset; Aux): Wet, 12Vdc, 1.2A max.; Dry (cut related jumper for dry contacts; see Wiring Dia-
gram), SPDT contacts 24Vdc, 2A, 0.6 PF
Auxiliary Power Output: 12Vdc regulated
Remote Power Output: 12Vdc regulated (for keypads)
Combined Standby Current (Remote Power + Aux. Power + Reset Relay Power): See following charts.
Note:
(1)
With 1 RBAT6 battery, GEM-P9600 combined standby current + PS3002 standby current may not exceed 1.2A.
(2)
W(2) With 2 RBAT6 batteries, GEM-P9600 combined standby current + alarm current may not exceed 1.9A.
Standby Time: Residential Fire/Burglary & Commercial Burglary, 24 hours minimum
EZM Module: GEM-EZM8: Input, 50mA (not including PGM output)
PGM Output: 5mA, 12V Special Application
Keypad Current:
GEM-RP1CAe2/GEM-K1CA: 100mA; 35mA if backlighting is disabled (cut W1, W2 & W3)
GEM-RP2ASe2/GEM-K2AS: 50 mA
GEM-RP3DGTL/GEM-K3DGTL: 50 mA
GEM-RP4RFC/GEM-K4RF: 75mA Standby
GEM-RP4C/GEM-K4: 45mA Standby
PGM Output: 5mA, 12V Special Application
Maximum Number of Keypads: 15
Maximum Wiring Length for each run (#22AWG): 1000' divided by total number of keypads and EZMs on run
Keypad Dimensions: 4" x 5" x 1" (H x W x D); 11.1cm
ORDERING INFORMATION
System Components
GEM-P9600: Residential UL-Listed Burg Control Panel.
GEM-RP1CAe2/GEM-K1CA: 32-Character LCD Burg & Residential Fire Keypad with 4 EOL Zones.
GEM-RP2ASe2/GEM-K2AS: LCD Burg & Residential Fire Keypad with remote panic.
GEM-RP3DGTL/GEM-K3DGTL: Digital Burg and Residential Fire Keypad with remote panic.
GEM-RP4RFC/GEM-K4RF: Digital Icon Burg and Residential Fire Keypad with Integral RF Receiver.
GEM-RP4C/GEM-K4: Digital Icon Burg and Residential Fire Keypad.
TRANSFORMER RECHARGEABLE
BATTERY
POWER
SUPPLY
GEM-P9600 COM-
BINED
STANDBY CURRENT
GEM-P9600
ALARM
CURRENT
POWER SUPPLY
STANDBY
CURRENT
STANDBY
TIME
TRF11 (16.5 VAC, 40 VA) RBAT4 (12 VDC, 4 AH) N/A 750 mA 2.0 A N/A 4 Hours
TRF11 (16.5 VAC, 40 VA) RBAT6 (12 VDC, 6 AH) N/A 750 mA 2.0 A N/A 6 Hours
TRF11 (16.5 VAC, 40 VA)
(3)
RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A)
750 mA
(1)
1.9 A
(2)
1.2 A
(1,2)
4 Hours
TRF11 (16.5 VAC, 40 VA)
(3)
2 RBAT6 (12 VDC, 6 AH) PS3002 (13.2 VDC, 1.9 A) 750 mA 1.9 A 1.4 A 4 Hours
RESIDENTIAL BURGLARY & COMMERCIAL BURGLARY
TRANSFORMER RECHARGEABLE
BATTERY
GEM-P9600
COMBINED
STANDBY CURRENT
GEM-P9600
ALARM
CURRENT
STANDBY
TIME
TRF11 (16.5 VAC, 40 VA) RBAT7 (12 VDC, 7 AH) 150 mA 650 mA 24 Hours
RESIDENTIAL FIRE, COMBINATION RESIDENTIAL FIRE & BURGLARY