GEM-P9600 Installation Instructions
WI742D 5/03
!
Page 9
SUMMARY OF UL REQUIREMENTS
Residential
!
Recognized Limited-Energy Cable for initiating, indicating and supplementary circuits.
!
Initiating loops supervised if longer than 3 feet
!
FT2200 End-of-Line Relay for Fire (if using 4-wire smoke detectors)
!Minimum alarm timeout of 5 minutes
!Maximum exit time: 60 seconds
!Maximum entry time: 45 seconds
!
Do not program “Swinger Shutdown”, “Force Arming”, “Selective Bypass”, “Group Bypass”, or “50 ms Loop
Response”
!
“Abort Delay” may not exceed 45 seconds
!
Program “Disable Callback Download”
!
Automatic dialer may not dial a police station number that has not been dedicated for such service
!
System must be tested at least weekly under AC/battery and Battery-Only conditions
!
Replace the rechargeable battery at least every 5 years
!
If the battery is heavily discharged, replace it or have it tested by a qualified technician
!For silent panic, connect only to UL-listed holdup devices
!All zones must be programmed for “Priority”
!Do not program any zones for “Keyswitch Arming”
!
System must be serviced at least once every year
!
Residential Fire and Combination Residential Fire & Burglary must program “Residential Fire”
!
Keypad Expansion (EZM) Zones are not to be used as fire zones
Compatible Smoke Detectors
2 Wire Smoke Detectors
Manufacturer Model Base
NAPCO FW-2 N/A
Sentrol/ESL 711U, 712U, 701U, 702U,
721U, 721UT, 702RE, 702RU
722U, 731U, 732U
System Sensor 1100, 1151, N/A
1400, 2100, N/A
2100T, 2100S, N/A
2100TS, 2151, N/A
2400, 2400TH N/A
Note:
Voltage Rating: 8.5–13.3 VDC
Maximum Number of Detectors: 10
4 Wire Smoke Detectors
Manufacturer Model Base
Gentex 812, 812T, 812P, N/A
812PT, 812PH, N/A
8120, 8120T, N/A
8120P, N/A
8120PTY, 8120-PH N/A
Hochiki SLG-12 w/YBC-RL4-RA base N/A
NAPCO FW-4 N/A
Sentrol/ESL 445AT, 445C, N/A
445CT, 445CR, N/A
445CRT N/A
System Sensor 1112, 2112, N/A
21112T, 211TSRB N/A
1412TH, 2412TH N/A
2312/24T, 1412, N/A
Note:
Subtract total smoke-detector alarm current
from available standby current.
UL Compatible Smoke Detectors (Providing UL Recognition or Listing)
Note: Any normally-open devices that do not require power from the control panel, such as pull stations,
waterflow and thermostats may be used if acceptable to the authority having jurisdiction.

Other manuals for Gemini GEM-P9600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gemini GEM-P9600 and is the answer not in the manual?

Gemini GEM-P9600 Specifications

General IconGeneral
BrandGemini
ModelGEM-P9600
CategorySecurity System
LanguageEnglish

Related product manuals