Error Message Diagnostics Screen
Text
Fault Description
Please Remove Cup Mug sensor error Cup not removed from dispense
area after vend completed
or faulty mug sensor
Sorry Out of Service
Please Insert Mug
No cup delivered ring 1
SureVend on/SureVend
error and must SureVend
Problem with CDU (cup jam)
No more cups being dispensed
Sorry Out of Service
Low Water
Low water Low water level in heater tank
Sorry Out of Service
Water Tank Heating
Water tank
heating
Water in the heater tank is below the
minimum vend temperature
Sorry Out of Service
Fill Timeout
Fill timeout/ low water Machine has been filling for 2 minutes and
not reached optimum level
Sorry Out of Service
Invalid Temp
Invalid temp 1. Comms error between I/O & MPU
2. Machine has exceeded optimum
boiler temp
3. Temperature probe fault
Sorry Out of Service
Brewer Jam
Brewer jam Brewer has not moved from its home
position and may be jammed
Sorry Out of Service
Brewer Not Homed
Brewer not homed Brewer has not returned to its home
position and may be jammed
Sorry Out of Service
Coin Mech Comm
Coin mech
comm
Communication error detected between
monetary device and machine
Sorry Out of Service
No Monetary Device
No monetary
device-fatal
Machine is configured for an incorrect
monetary device, or the device
is not responding
Temporarily
Out Of Service
Coin mech ROM MDB coin mech ROM checksum
test failed (fatal error)
Temporarily
Out Of Service
Coin mech accept
unplugged
MDB coin mech is
unplugged or faulty
Temporarily
Out Of Service
Coin mech accept
jam
Coin jam detected in coin acceptor
Temporarily
Out Of Service
Coin mech
payout jam
Coin jam detected in coin tube
Temporarily
Out Of Service
Coin mech
tube sensor
Coin tube sensor fault detected
Temporarily
Out Of Service
Coin mech all
tubes error
No useable coin tubes. Machine
unable to pay out
Technical Manual
120