Error Message Diagnostics Screen
Text
Fault Description
Sorry Out of Service
Head Not Homed
Head not homed Dispense head has not returned to
home position in expected time
Sorry Out of Service
Head not extended
Head Not Extended Dispense head has not fully
extended in the expected time
Sorry Out of Service
Waste Tray full
Waste tray full Waste tray Full
Temporarily
Out of Service
Init failed restart Machine failed on initialisation
Sorry Out of Service
No IO Comm
No IO comm Comms error detected between
mpu and I/O board
Initialising - CoEx® brewer not situated
correctly in the machine
Temporarily
Out Of Service
All selections
disabled
All drink selections have been disabled
Sorry Out of Service
Rinsing
Rinsing Automatic or manual rinse
cycle in progress
- Rinsing A rinsing cycle was interrupted
and not completed
Out Of Cups
Please Insert Mug
Cup turret/no cups/
no cups
Unable to find cup stack.
Cup turret has timed-out on initialisation
Sorry Out of Service
No Cups
No cups and mug
sensor failure
Machine is out of cups and
mug sensor is faulty
Out Of Cups
Please Insert Mug
No cups/no cups No cups are available but the mug
sensor is working
Temporarily
Out Of Service
No cup delivered
SV on
Non fatal error detected with
SureVend cup mechanism
Sorry Out of Service
Please Remove Cup
Mug sensor error/
please remove cup
An error has occurred with the SureVend
sensor during a vend
Sorry Out of Service
Mug Sensor Error
SureVend error and
must SureVend
No cups remaining and fault
with mug sensor
Section 12 - Diagnostics and Maintenance Procedures
12.1 Diagnostics
The following pages list the error messages that may be displayed, diagnostics messages
accessed via the engineers program and fault descriptions. For further help and advice
please contact the Crane Merchandising Systems Technical Support Helpline on 01249
667323.
Technical Manual
119