EasyManuals Logo
Home>Gree>Inverter>SXVD200LCJ/A-K

Gree SXVD200LCJ/A-K User Manual

Gree SXVD200LCJ/A-K
391 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #102 background imageLoading...
Page #102 background image
GMV5 Home DC Inverter Multi VRF Units
96
setting value of
water
temperature
keeping function
for water tank
standby status
P50
Water
temperature
setting of
sunflower water
temperature
keeping function
35~50℃
40℃
P53
Corrected value
of water heating
water
temperature auto
setting
-2~8℃
0℃
P54
Cycling days of
high-temperature
sterilizing
0~60
0
If it is set to 0, high-temperature
sterilizing function is valid only once.
P55
Advanced
startup time of
high-temperature
sterilization
0~3 hours
1
P56
On/Off of electric
heating under
normal water
heating
00: ON
01: OFF
00
P58
On/Off of auto
heat recovery
00: ON
01: OFF
00
P59
Water
temperature
setting of auto
heat recovery
35~46℃
42℃
P73
On/Off of rapid
heating
00: ON
01: OFF
01
P80
On/Off of electric
heating for floor
heating
00: ON
01: OFF
00
Note:
In parameter setting status, "WATER/AC/FLOOR" and "TIMER" buttons are invalid. By
pressing "ON/OFF" button, user can return to the main interface but not power on or off the unit.
4.4 Operation Instructions
4.4.1 Switch between Water Heating Interface and Floor Heating
Interface
Under any status with no other operation (If there is other operation, please exit first), press

Table of Contents