EasyManuals Logo
Home>Gree>Inverter>SXVD200LCJ/A-K

Gree SXVD200LCJ/A-K User Manual

Gree SXVD200LCJ/A-K
391 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #252 background imageLoading...
Page #252 background image
GMV5 Home DC Inverter Multi VRF Units
246
heating is turned
on in normal
operation
P58
Whether the auto
heat recovery is
allowed
00: allowed
01: not allowed
00
P59
Auto heat
recovery water
temperature
setting
35 ~ 46℃
42℃
P73
Whether the fast
heating mode is
allowed
00: allowed
01: not allowed
01
P80
Whether floor
heating auxiliary
heating is allowed
to start up
00: allowed
01: not allowed
00
P81
Maximum setting
value of floor
heating water
yielding
temperature
40~52℃
45℃
Notes:
Under parameter setting status, ―heating water/air conditioner/floor heating‖, and ―Timer‖
buttons are invalid. By pressing the ―ON/OFF‖ button, users can return to the main interface but
will not turn on/off the unit.
Engineering parameter inquiry
Engineering parameters can be inquired in power-on or power-off status.
1) Press and hold ―Function‖ button for five seconds to enter into engineering parameter
inquiry interface. The temperature area displays ―C00‖, and ―View‖ icon is on;
2) Within five seconds after ―C00‖ is displayed, continuously press the ―Mode‖ button for three
times in an interval within one second to enter into engineering parameter inquiry.
3) Select a parameter code by pressing ― ‖ or ― ‖.
4) Press ―Enter/Cancel‖ button to return to the upper level menu till quitting parameter inquiry.
In the engineering parameter inquiry interface, users can also inquire user parameters.
The engineering parameter inquiry list is as below:
Engineering Parameter Inquiry List
Paramet
er Code
Parameter
Name
Parameter
Range
View Method
C00
Parameter
setting
ingress
-
Under ―C00‖ status, timer area displays the engineering number of
the current hydro box, when one wired controller controls multiple
hydro boxes at the same time, it will only display the engineering
number of hydro box with the minimum number;
C02
Water tank
capacity
inquiry
150
~3500L
Operating method:
Enter into the inquiry, under ―C02‖ status, press ―Mode‖ button to
enter into water tank capacity inquiry interface, press ―▲‖ and ―▼‖ to
switch hydro box.
Display method:

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree SXVD200LCJ/A-K and is the answer not in the manual?

Gree SXVD200LCJ/A-K Specifications

General IconGeneral
BrandGree
ModelSXVD200LCJ/A-K
CategoryInverter
LanguageEnglish

Related product manuals