GMV5 Home DC Inverter Multi VRF Units
75
01: High height of
ceiling installation
Setting of timer
function
00: Common
timing
01: Time-point
timing
Effectiveness of
repeated
time-point timing
00: Single timing
01: Repeat every
day
This setting is valid only when the timer
function is set to time-point timing.
Cooling
temperature
setting for auto
mode
Cooling set temperature – Heating set
temperature ≥1
Note: The two settings are still valid in
remote shielding status.
Heating
temperature
setting for auto
mode
Setting of
preferential
operation
00: Common
operation
01: Preferential
operation
When power supply is insufficient, indoor
units that are set with preferential operation
can be turned on or off at will while other
indoor units will be powered off forcibly. Error
code will be displayed on the unit that is
forcibly stopped.
Clearing of
accumulated time
for air filter
cleaning
00: Not cleared
01: Cleared
Setting of
superfast
defrosting
00: Common
defrosting
01: Superfast
defrosting 1
02: Superfast
defrosting 2
Note: Superfast defrosting function is only
applicable to models whose jumper cap is
10, 13, 14, 15, 16, 17, 18, 19, 20, 21, 22
Setting of opening
angle for indoor
unit air return
panel
01: Angle 1 (25°)
02: Angle 2 (30°)
03: Angle 3 (35°)
Only applicable to some models
Setting of cooling
air discharge
temperature for
fresh air indoor
unit
Only applicable to fresh air indoor unit
Setting of heating
air discharge
temperature for
fresh air indoor
Only applicable to fresh air indoor unit