5. Parameter Setting
5-24
Menu Menu title Description Unit Range Default
*P7-06 MPG Pulse[REV] User 0~100000 100
Set command pulse or MPG pulse input quantity.
Ex) If set to P7-05=1, P7-06=100, when MPG pulse is putted 100 pulse motor rotates one
revolution
Namely, pulse number/one revolution= P7-06/P7-05= 100 pulse / 1 rotation
Menu Menu title Description Unit Range Default
*P7-07 Angle Division
Angle division stop
when Jog operation
User 0~1000 0
When using turret operation mode, as in the case of stopping in JOG operation, Set the ordinary
rate of the angle that is stopped.
Ex) If set value=30
When operating in JOG Mode, as in the case of inputting the stop command in optional
angle only stop the multiples of 30 degree which is set
(Danger !) RUN_MODE[P8-01]: Only applied in zero turret operation Digital Loader
As in the case of IJOG transportation by Digital Loader and stop by input contact
point STOP. Angle-division-stop doesn’t operate

Table of Contents